摘要 建筑整体气密性在近零能耗建筑中的节能潜力巨大,掌握建筑整体气密性的影响因素及作用方式,对改善气密性水平非常重要。概论并对比国内外气密性实验的研究现状,指出目前国内气密性研究偏重部件研究而忽视整体研究、偏重模拟而忽视实验的现状研究,在此基础上总结了建筑整体气密性主要影响因素,梳理了气密性研究的现状不足之处和预期研究方向。 The airtightness of the building has prior potential for energy saving in the study of the current nearly-zero energy buildings.This paper introduces and compares the status quo of researches concerning impact factors both at home and abroad.The domestic research on impact factors of airtightness focuses on simulation and component research,ignoring the experiments and integral airtightness.On this basis,the main impact factors of the integral airtightness in the buildings are summarized with the existing deficiencies and expected research directions of the air tightness research sorted out,which lays a foundation for the future research of the integral air tightness of domestic buildings.
作者 李扬捷 徐伟 董宏 LI Yang-jie;XU Wei;DONG Hong(Institute of Building Environment and Energy,China Academy of Building Research,Beijing 100013,China)
出处 《建筑节能》 CAS 2020年第8期65-69,90,共6页 BUILDING ENERGY EFFICIENCY
基金 国家自然科学基金资助项目(2017YFC0702601-02)
关键词 整体气密性 气密性实验 空气渗漏 integral airtightness airtightness experiment infiltration
  • 相关文献

参考文献5

二级参考文献33

  • 1田雁晨,孙冬梅,刘刚.建筑围护结构气密性检测方法研究[J].绿色建筑,2010,2(6):36-39. 被引量:15
  • 2钟珂,王琦,亢燕铭.夏热冬冷地区冬季供暖方式的选择[J].暖通空调,2004,34(12):70-73. 被引量:17
  • 3赵群,周伟,刘加平.中国传统民居中的生态建筑经验刍议[J].新建筑,2005(4):7-9. 被引量:45
  • 4中国建筑科学研究院.JGJ26-2010严寒和寒冷地区居住建筑节能设计标准[S].北京:中国建筑工业出版社,2010.
  • 5中国建筑科学研究院.JGJ134-2010《夏热冬冷地区居住建筑节能设计标准》[S].北京:中国建筑工业出版社,2010.
  • 6Steeman M, Janssens A, Steeman H J. On coupling 1D non-isothermal heat and mass transfer in porous materials with a multizone building energy simulation model[J ]. Building and Environment, 2010,45 (4) : 865- 877.
  • 7Hagentoft C E, Harderup E. Moisture conditions in a north-facing wall with cellulos loose-fill insulation: construction with and without a vapor retarder and air leakage[G]//ASHRAE Tram, 1995,101(1) : 639- 646.
  • 8J anssens A, Hens H. Interstitial condensation due to air leakage:a sensitivity analysis[J]. Journal of Thermal Envelope and Building Science, 2003,27 (1) : 15- 29.
  • 9Kong Fanhong, Wang Huaizhu, Zhang Qunli. Heat and mass coupled transfer combined with freezing process in building exterior envelope f-J]. Applied Mechanics and Materials, 2011,71 (4) : 3385- 3388.
  • 10Nazaroff W W,DoyleS M. Radon entry into houses having a crawl space[J]. Health Physics, 1985, 48 (3) :265-281.