1[1]Lindner, Jonathan R. Detection of inflamed plaques with contrast ultrasound. [J]. The American Journal of Cardiology Volume, 2002, 90(10): L32-L35.
2[2]Hohmann J, Albrecht T, Hoffmann C W, etc. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents. [J].European Journal of Radiology, 2003, 46: 147-159.
3[3]Esteban J M, Molla C, Tomas L. Improved detection of liver metastases with contrast-enhanced wideband harmonic imaging: comparison with CT findings. [J]. European Journal of Ultrasound, 2002, 15:119-126.
4[4]Christiansen Jonathan P, Brent A. Alexander L. etc.Targeted tissue transfection with ultrasound destruction of plasmid-bearing cationic microbubbles. [J]. Ultrasound in Medicine and Biology, 2003, 29(12): 1759-1767.
5[5]Shin-ichiro Miura, Katsaro Tachibana, Takahiro Okamoto,etc. In vitro transfer of antisense oligodeoxynucleotides into coronary endothelial cells by ultrasound. [J]. Biochemical and Biophysical Research Communications, 2002, 298:587-590.
6[6]Gawiyou Danialou, Alain S, Roy W R, et al. Ultrasound Increases Plasmid-Mediated Gene Transfer to Dystrophic Muscles without Collateral Damage. [J]. Molecular therapy,2002, 6(5): 687-693.
7[7]Evan C Unger, Thomas P McCreery, Robert H Sweitzer, etc.In Vitro Studies of a New Thrombus-Specific Ultrasound Contrast Agent. [J]. The american journal of cardiologyt,1998, 81(12A): 58g-61g.
8[8]Ziskin MC, Bonakdapour A, Wienstein DP, et al. Contrast agents for diagnostic ultrasound. [J]. Invest Radiol. 1972,7:500.
9[9]Christian Veltmann, Stefan Lohmaier, Thomas Schlosser, et al. On The design of a capillary flow phantom for the evaluation of ultrasound contrast agents at very low flow velocities.[J]. Ultrasound in Med. & Biol., 2002, 28(5):625-634.
10[10]Wheatley M A, Singhal S. Structural studies on stabilized microbubbles: development of a novel contrast agent for diagnostic ultrasound. [J]. Reactive polymers, 1995, 25:157-166.
4Ditrich HC, Bales GL, Kuvelas T, et al. Myocardial perfusion using new intravenous ultrasound contrast agents:congparision between video and intefrated backscatter images with a prototype software program. Am Coll Cardiol, 1994, 23: 393A.
5Porter TR, Xei F, Kilzer K. Intravenous perfluoropropaneexosed sonicated dextrose albumin produces myocadil ultrasound contast that correlaes with coronary blood flow. Am Doc Echocardiogr, 1995, 8: 710-718.
6北原文雄.表面活性剂.孙绍增.译.北京:化学工业出版社,1984:48-49.
7Porter T, Kricsfeld, Cheathams, et al. Effect of blood and microbubble oxgen and nitrogen content on perfluocarbon-filled dextrose album microbubble size and efficary in vitro and vivo studies. Am Soc Echocardioger, 1998, 11 (5): 421-425.
8VANBOUTTE P M. Endothelial dysfunction and atherosclerosis[J]. Journal of European Heart, 1997, 18: 19-29.
9BIEGELSEN E S, LOSCALZO J. Endothelial fimction and atherosclerosis[J]. Coronary Artery Disease, 1999, 10: 214-256.
10TADDEI S, SALVETTI A. Endothelial dysfunction in essential hypertension: clinical implications[J]. Journal of Hypertension, 2002, 20:1671-1674.