摘要
文章对NF-6风洞AV90-2轴流压缩机防喘振监控系统进行了分析研究。重点讨论了防喘振机理、监控系统结构和喘振测试方法,并且基于此系统进行了AV90-2轴流压缩机喘振曲线测试。结果表明:①该防喘振监控系统能够保障风洞安全运行要求,为压缩机的喘振曲线测试和风洞正常实验奠定了坚实的基础;②采用体积流量作为喘振曲线的控制流量是合理的,常压和增压的喘振边界点几乎重合;③常压防喘振曲线可以保障风洞在不同总压下的安全运行。
Aim.It is imperative to ensure safety in operating the NWPU NF-6 wind tunnel(a pressurized continuous transonic airfoil wind tunnel).Hence we measure and investigate the surge curve of the AV90- 2 axial compressor.Fig.1 in section 1 of the full paper presents the schematic of NF-6 wind tunnel. Section 2 briefs the anti-surge mechanism.Fig.3 in section 3 presents the block diagram of the monitor and control system in NF-6 wind tunnel.Fig.4 in section 4 gives the measured surge boundary curve and anti-surge c...
出处
《西北工业大学学报》
EI
CAS
CSCD
北大核心
2009年第4期477-480,共4页
Journal of Northwestern Polytechnical University
基金
翼型
叶栅空气动力学国家重点实验室基金(9140C4202020604)资助
关键词
监控系统
防喘振曲线
NF-6风洞
wind tunnels
control systems
compressors
anti-surge curve