1[1]Takama N, Kuriyama T, Shiroko K, et al. [ J ]. Comp Chem Engng,1980,4:251 - 258.
2[2]Wang Y P, Smith R. [J]. Chem Eng Sci, 1994,49(7):981 - 1006.
3[3]Wang Y P, Smith R. [J]. Tran Inst Chem Eng, 1995,73(Part A):889 - 904.
4[4]Kuo W C J,Smith R. [J] .Trans Inst Chem Eng,1998,76(Part A) :287-301.
5[5]Olesen S G, Polley S G. [ J]. Trans Inst Chem Eng, 1997,75(Part A):420 - 426.
6[6]Kuo J, Smith R. [ J]. Trans Inst Chem Eng, 1998,76 ( Part A): 287 -301.
7[7]Huang C H, Chang C T, Ling H C, et al. [J]. Ind Eng Chem Res,1999,38: 2666 - 2679.
8[8]Bagajewicz M J, Rivas M, Savelski M J. A new approach to the design of water utilization systems with multiple contaminants in process plants[A]. In: AICHE National Meeting[ C ]. Dallas, 1999.
9[9]Savelski M, Bagajewicz M. A new algorithmic design procedure for the design of water utilization systems in refineries and process plants[A].In: Proceedings of PRESS 99 Meeting[ C ]. Budapest, 1999.
10[10]Savelski M, Bagajewicz M. On the use of linear models for the design of water utilization systems in refineries and process plants[ A]. In:Annual AIChE 1999 Meeting[ C]. Dallas, 1999.
同被引文献20
1Wang Y P, Smith R. Wastewater mini-mization[J]. Chemical Engineering Science, 1994, 49(07): 981-1006.
2Feng X, Bai J, Zheng X S. On the use of graphical method to determine the targets of single-contaminant regeneration recycling water systems[J] Chemical Engineering Science, 2007, 62(08): 2127-2138.
3Klemes J J. Industrial water recycle/reuse[J]. Curt Opin Chem Eng, 2012, 1(3): 238-245.
4Prakash R K, Shenoy U V. Targeting and design of water networks for fixed flowrate and fixed contaminant load operations[J]. Chon Eng Sci, 2005, 60(01): 255-268.
5Deng C, Feng X. Process-basad graphical approach for simultaneous targeting and design of water network[J]. AIChE Journal, 2011, 57(11): 3085-3104.
6Fang X, Bai J, Wang H M, Zheng X S. Grass-roots design of regenera- tion recycling water networks[J]. Computers & Chemical Engineering, 2008, 32(08): 1892-1907.
7Ng D K S, Foo D C Y, Tan R R, Tan Y L. Ultimate fiowrate targeting with regeneration placement[J]. Chemical Engineering Research and De- sign, 2007, 85(09): 1253-1267.
8Tan R R, Ng D K S, Foo D C Y, Aviso K B. A superstructure model for the synthesis of single-contaminant water networks with partitioning re- generators[J]. Process Safety and Environmental Protection, 2009, 87(03): 197-205.
9Zhan H P, Fan X Y, Liu Z Y. Design of regeneration recycling water networks with internal water mains by using concentration potential concepts[J]. Chemical Engineering Science, 2013, 91 (02): 162-172.
10Li A H, Yang Y Z, Liu Z Y. Analysis of water-using networks with multi- ple contaminants involving regeneration recycling[J]. Chemical Engi- neering Science, 2015, 134(09): 44-56.