摘要
基于钢制薄壁内压容器模糊静强度的信息熵分析,从控制钢制薄壁内压容器模糊静强度在正常操作与压力试验时模糊可靠度的角度,对其安全系数与试验压力系数进行探索。研究表明,从等可靠度的观点,(1)钢制薄壁内压容器模糊屈服强度可靠度在正常操作时应不低于0.99354,在气压与液压试验时应分别不低于0.97260与0.7925;模糊爆破强度可靠度在正常操作时应不低于0.99999999140,在气压与液压试验时应分别不低于0.99999999140与0.999990226。(2)钢制薄壁内压圆筒屈服安全系数应不小于1.45,抗拉安全系数应不小于1.80;钢制薄壁内压球形容器屈服安全系数应不小于1.40,抗拉安全系数应不小于1.85;扁平绕带式容器屈服安全系数应不小于1.35,抗拉安全系数应不小于1.95。(3)钢制薄壁内压圆筒试验压力系数在气压试验时应不小于1.04,但不大于1.16;在液压试验时应不小于1.04,但不大于1.26。钢制薄壁内压球形容器试验压力系数在气压试验时应不小于1.04,但不大于1.19;在液压试验时应不小于1.04,但不大于1.26;扁平绕带式容器试验压力系数在气压试验时应不小于1.04,但不大于1.16;在液压试验时应不小于1.04,但不大于1.28。
The fuzzy static strength reliability,safety factor and testing pressure coefficient of steel thinness wall internal pressure vessels during normal operation and pressure tests were quantitatively analyzed based on the information entropy theory.From the equal-reliability point of view,the researching results show that:①For fuzzy yield strength reliability of steel thinness wall internal pressure vessels,the desirable value should be not less than 0.993 54 during normal operation,and the desirable values no...
出处
《机械强度》
CAS
CSCD
北大核心
2010年第2期260-264,共5页
Journal of Mechanical Strength
基金
湖北省教育厅科研项目(B20087301)
武汉市教育局重点科研项目(2008K027)
武汉市创新人才开发资金重大创新专项资助项目~~
关键词
薄壁内压容器
模糊静强度
模糊可靠度
试验压力系数
安全系数
信息熵
Thinness wall internal pressure vessels
Fuzzy static strength
Fuzzy reliability
Testing pressure coefficient
Safety factor
Information entropy