期刊文献+

Flow Injection Semi-online Preconcentration Graphite Furnace Atomic Absorption Spectrometry for Determination of Cadmium,Copper and Manganese 被引量:3

Flow Injection Semi-online Preconcentration Graphite Furnace Atomic Absorption Spectrometry for Determination of Cadmium,Copper and Manganese
在线阅读 下载PDF
导出
摘要 A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements. The analytical performances of the prospsed method for determining Cd, Cu and Mn were studied. The analytes were preconcentrated with a thiol resin(Type 190, produced by Nankai University, China) whose active group is -SH. The elements to be determined were preconcentrated onto the column for 60 s and then rinsed with deionized water and eluted with 30 μL of 1 mol/L HCl. The graphite furnace atomic absorption spectrometry(GFAAS) determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle. Enrichment factors 41, 22 and 20 and detection limits(3 σ , n =10) 0.36, 3.8 and 7.0 ng/L for Cd, Cu and Mn, respectively, along with a sampling frequency of 20 h -1 , were obtained with a 60 s loading time at a sample flow rate of 3.5 mL/min. The analytical results for a number of water samples show that the flow-injection semi-online column preconcentration can not only eliminate the effect of some concomitant elements, such as Li, Na, K, Ca and Mg, on the determination of the analyte, but also enhance the sensitivity. A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements. The analytical performances of the prospsed method for determining Cd, Cu and Mn were studied. The analytes were preconcentrated with a thiol resin(Type 190, produced by Nankai University, China) whose active group is -SH. The elements to be determined were preconcentrated onto the column for 60 s and then rinsed with deionized water and eluted with 30 μL of 1 mol/L HCl. The graphite furnace atomic absorption spectrometry(GFAAS) determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle. Enrichment factors 41, 22 and 20 and detection limits(3 σ , n =10) 0.36, 3.8 and 7.0 ng/L for Cd, Cu and Mn, respectively, along with a sampling frequency of 20 h -1 , were obtained with a 60 s loading time at a sample flow rate of 3.5 mL/min. The analytical results for a number of water samples show that the flow-injection semi-online column preconcentration can not only eliminate the effect of some concomitant elements, such as Li, Na, K, Ca and Mg, on the determination of the analyte, but also enhance the sensitivity.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2002年第1期1-7,共7页 高等学校化学研究(英文版)
关键词 FLOW-INJECTION Semi-online preconcentration Atomic absorption spectrometry Cadmium Copper Manganese Flow-injection, Semi-online preconcentration, Atomic absorption spectrometry,Cadmium,Copper,Manganese
  • 相关文献

参考文献36

  • 1Sturgeon R E.查看详情,1989.
  • 2Fang Z.查看详情,1993.
  • 3Fang Z.Flow Injection Atomic Absorption Spectrometry,1995.
  • 4Fang Z;Sperling M;Welz B.查看详情[J],1990.
  • 5Sperling M;Yin X;Welz B.查看详情[J],1991.
  • 6Welz B.查看详情[J],1992.
  • 7Su X;Zhang H;Liang F.查看详情[J],1999.
  • 8Azeredo L C;Sturgeon R E;Curtius A J.查看详情[J],1993.
  • 9Tao G;Fang Z.查看详情[J],1995.
  • 10van Duijneveldt F B;van Duijneveldt-van de Rijdt J G C M;van Lenthe J H.查看详情,1994(07).

共引文献3

同被引文献4

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部