回复电压法用于变压器油纸绝缘老化状态评估 被引量:23

Transformer Oil-Paper Insulation Ageing Condition Assessment Using Return Voltage Measurements
在线阅读 下载PDF
导出
摘要 油纸绝缘材料发生老化现象时,往往会引起固体绝缘纸板材料中含水量增加及绝缘系统电介质响应特性改变。若对其进行回复电压测量,会表现出峰值升高、起始斜率增大以及峰值时间缩短等定性特征。为了进一步量化油纸绝缘老化现象与回复电压之间的关系,在介绍回复电压法基本原理的基础上,针对实验室内不同老化程度和不同含水量的油纸绝缘系统进行了回复电压试验,并结合现场实测经验,提出了基于回复电压的油纸绝缘老化状态评估方法。结果表明,油纸绝缘老化或受潮会显著降低其极化谱的主时间常数,绝缘固体材料的含水量与主时间常数的对数之间存在定量关系,利用主时间常数可以有效评估油纸绝缘的老化状态。 Aging of oil-paper insulation materials leads to an substantial increase of the water content in the solid insulation and changes of the dielectric response characteristics.If return voltage measurement(RVM) is performed on the ageing insula-tion system,some qualitative features i.e.,higher peak value,greater initial slope and longer peak time can be found.On the basis of the introduction of the basic theory of dielectric resp-onse,some oil-paper samples are measured by RVM under different ageing and moisture states to identify the relationship between the oil-paper insulation ageing condition and RVM.The results show that the dominant time constant decreases significantly when oil-paper insulation gets aged or moistened,and there is a quantitative relationship between the moisture in the solid insulation and the dominant time constant,and the aging condition of the oil-paper insulation can be effectively diagnosed by making use of the dominant time constant.
出处 《电网与清洁能源》 2012年第9期6-12,共7页 Power System and Clean Energy
基金 国家高技术研究发展计划(2007AA04Z411) 国家自然科学基金(50907051)~~
关键词 回复电压 油纸绝缘 绝缘老化 主时间常数 状态评估 return voltage oil-paper insulation insulation ageing dominant time constant condition assessment
  • 相关文献

参考文献19

二级参考文献57

  • 1崔雪梅,孙才新,李新,杜林,李剑.实小波与复小波变换对局部放电在线监测中提取信号特征的特点研究[J].电工技术学报,2004,19(7):90-94. 被引量:18
  • 2王颂,李香龙,李军浩,赵晓辉,李彦明.变压器局部放电超高频信号外传播特性的试验研究[J].高压电器,2007,43(2):100-101. 被引量:26
  • 3李军,董立文,赵红.油浸式变压器的老化和寿命评估[J].高电压技术,2007,33(3):186-187. 被引量:34
  • 4DL/T596-1996电力设备预防性试验规程[S].北京:中国电力出版社,1996.
  • 5WHITE S.Life Management of Primary Distribution Transformers[J].IEE Colloquium on Transformer Life Management,1998,5(1-5):11.
  • 6SAHA T K.Review of Time-domain Polarization Measurements for Assessing Insulation Condition in Aged Transformers[J].IEEE Transactions on Power Delivery,2003,18(4):1293-1301.
  • 7EKANAYAKE C,GUBANSKI S M,MULARACHCHI K D,et al.Diagnostic of Power Transformers in Sri Lanka:Application of Dielectric Spectroscopy in Frequency Domain[C]//Proceedings of Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference.2001:593-596.
  • 8LINHJELL D,GAFVERT U,LUNDGAARD L E.Dielectric Response of Oil-impregnated Paper Insulation:Variation with Humidity and Ageing Level[C]//Annual Report Conference on Electrical Insulation and Dielectric Phenomena.2004:262-266.
  • 9YEW J H,SAHA T K,THOMAS A J.Impact of Temperature on the Frequency Domain Dielectric Spectroscopy for the Diagnosis of Power Transformer Insulation[C]//IEEE Power Engineering Society General Meeting,2006:1-7.
  • 10LINHJELL D,LUNDGAARD L.Dielectric Response of Mineral Oil Impregnated Cellulose and the Impact of Aging[J].IEEE Transactions on Dielectrics and Electrical Insulation,2007,14(1):156-169.

共引文献154

同被引文献299

引证文献23

二级引证文献229

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部