摘要 Replacement of gastrostomy tube in patients under-going percutaneous endoscopic gastrostomy (PEG) is generally considered as a safe and simple procedure. However, it could be associated with serious complications, such as gastrocutaneous tract disruption and intraperitoneal tube placement, which may lead to chemical peritonitis and even death. When PEG tube needs a replacement (e.g., occlusion or breakage of the tube), clinicians must realize that the gastrocutaneous tract of PEG is more friable than that of surgical gastrostomy because there is no suture fixation between gastric wall and abdominal wall in PEG. In general, the tract of PEG begins to mature in 1-2 wk after placement and it is well formed in 4-6 wk. However, this process could take a longer period of time in some patients. Accordingly, this article describes three major principles of a safe PEG tube replacement: (1) good control of the replacement tube along the well-formed gastrocutaneous tract; (2) minimal insertion force during the replacement, and, most importantly; and (3) reliable methods for the confirmation of intragastric tube insertion. In addition, the management of patients with suspected intraperitoneal tube placement (e.g., patients having abdominal pain or signs of peritonitis immediately after PEG tube replacement or shortly after tube feeding was resumed) is discussed. If prompt investigation confirms the intraperitoneal tube placement, surgical intervention is usually required. This article also highlights the fact that each institute should have an optimal protocol for PEG tube replacement to prevent, or to minimize, such serious complications. Meanwhile, clinicians should be aware of these potential complications, particularly if there are any difficulties during the gastrostomy tube replacement. Replacement of gastrostomy tube in patients under-going percutaneous endoscopic gastrostomy (PEG) is generally considered as a safe and simple procedure. However, it could be associated with serious complications, such as gastrocutaneous tract disruption and intraperitoneal tube placement, which may lead to chemical peritonitis and even death. When PEG tube needs a replacement (e.g., occlusion or breakage of the tube), clinicians must realize that the gastrocutaneous tract of PEG is more friable than that of surgical gastrostomy because there is no suture fixation between gastric wall and abdominal wall in PEG. In general, the tract of PEG begins to mature in 1-2 wk after placement and it is well formed in 4-6 wk. However, this process could take a longer period of time in some patients. Accordingly, this article describes three major principles of a safe PEG tube replacement: (1) good control of the replacement tube along the well-formed gastrocutaneous tract; (2) minimal insertion force during the replacement, and, most importantly; and (3) reliable methods for the confirmation of intragastric tube insertion. In addition, the management of patients with suspected intraperitoneal tube placement (e.g., patients having abdominal pain or signs of peritonitis immediately after PEG tube replacement or shortly after tube feeding was resumed) is discussed. If prompt investigation confirms the intraperitoneal tube placement, surgical intervention is usually required. This article also highlights the fact that each institute should have an optimal protocol for PEG tube replacement to prevent, or to minimize, such serious complications. Meanwhile, clinicians should be aware of these potential complications, particularly if there are any difficulties during the gastrostomy tube replacement.
出处 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第1期14-18,共5页 世界胃肠内镜杂志(英文版)(电子版)
基金 Supported by Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
关键词 PERCUTANEOUS ENDOSCOPIC GASTROSTOMY GASTROSTOMY TUBE replacement GASTROSTOMY TUBE exchange GASTROSTOMY TUBE reinsertion COMPLICATION PERITONITIS Prevention Management Percutaneous endoscopic gastrostomy Gastrostomy tube replacement Gastrostomy tube exchange Gastrostomy tube reinsertion Complication Peritonitis Prevention Management
  • 相关文献

参考文献70

  • 1David I. Gaines MD,Mark H. Delegge MD.Semiurgent Endoscopic PEG Tube Replacement as a Treatment for Early Initial PEG Tube Dislodgement in the Immune-Compromised Patient[J]. Digestive Diseases and Sciences . 2005 (12)
  • 2Jeffrey M. Barkmeier,Scott O. Trerotola,Eric A. Wiebke,Stuart Sherman,Veronica J. Harris,John J. Snidow,Matthew S. Johnson,Wendy J. Rogers,Xiao-Hua Zhou.Percutaneous Radiologic, Surgical Endoscopic, and Percutaneous Endoscopic Gastrostomy/Gastrojejunostomy: Comparative Study and Cost Analysis[J]. CardioVascular and Interventional Radiology . 1998 (4)
  • 3Jeffrey L. Ponsky M.D.,Michael W. L. Gauderer M.D..Percutaneous endoscopic gastrostomy: Indications, limitations, techniques, and results[J]. World Journal of Surgery . 1989 (2)
  • 4Cappell,MS,Godil,A.A multicenter case controlled study of percutaneous endoscopic gastrostomy in HIV seropositive patients. The American journal of Gastroenterology . 1993
  • 5Rebecca L Delegge,Mark H. Delegge.Percutaneous endoscopic gastrostomy evaluation of device materials:are we "Failsafe"?. Nutrition in Clinical Practice . 2005
  • 6Sartori,S,Trevisani,L,Nielsen,I,Tassinari,D,Ceccotti,P,Abbasciano,V.Longevity of silicone and polyurethane catheters in long-term enteral feeding via percutaneous endoscopic gastrostomy. Alimentary Pharmacology and Therapeutics . 2003
  • 7Gauderer MW,Ponsky JL,Izant RJ Jr.Gastrostomy without laparotomy: a percutaneous endoscopic technique. Journal of Pediatric Nursing . 1980
  • 8ASPEN Board of Directors and the Clinical Guidelines Task Force.Guidelines for the use of parenteral and enteral nutrition in adult and pediatric patients. Journal of Parenteral and Enteral Nutrition . 2002
  • 9Seldinger S I.Catheter replacement of the needle in percutaneous arteriography: A new technique. Acta Radiologica . 1953
  • 10J Blacka,J Donoghue,M Sutherland,I Martincich,S Mitten-Lewis,P Morris.Dwell time and functional failure in percutaneous endoscopic gastrostomy tubes: a prospective randomized-controlled comparison between silicon polymer and polyurethane percutaneous endoscopic gastrostomy tubes. Alimentary Pharmacology and Therapeutics . 2004

共引文献2

同被引文献37

引证文献4

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部