期刊文献+

采用低剂量扫描条件和低剂量对比剂行128层螺旋CT头颈部动脉成像的可行性研究 被引量:5

Feasibility of low-dose radiatio and low volume contrast medium protocol in cerebral and carotid angiography with 128-slice CT
在线阅读 下载PDF
导出
摘要 目的探讨采用低剂量扫描条件和低剂量对比剂进行128层螺旋CT头颈部动脉造影的可行性。方法将100例接受头颈部CT血管造影(CTA)检查的患者随机分为研究组和对照组,管电压、管电流和对比剂用量分别为100 kV、300 mA、50 ml和120 kV、450 mA、70 ml,对比分析图像质量、血管强化情况、静脉硬化伪影及辐射剂量、对比剂剂量。结果①除右侧锁骨下动脉外,各主要动脉节段影像评分两组间差异无统计学意义(P>0.05);②研究组CT值高于对照组(P<0.05);③对照组静脉伪影较研究组明显(P<0.05)。④对照组辐射剂量及对比剂用量明显高于研究组(P<0.05)。结论采用低剂量扫描条件和低剂量对比剂进行头颈部128层螺旋CTA可获得较好的图像质量。 Objective To evaluate the feasibility of low-dose radiation and low volume contrast medium pro-tocol for cerebral and carotid CTA with 128-slice spiral CT scanner.Methods Totally 100 patients who underwent cere-bral and carotid CTA were included and divided randomly into experimental group and control group,with the tube voltage of 100kVand 120kV,tube current of 300mA and 450mA,and contrast medium of 50mland 70ml,respectively. Image quality,vascular enhancement,venous artifacts as well as the radiation dose were independently compared be-tween the two groups.Results ①There was no significant difference of image quality of the cerebral and carotid ar-teries except for the right subclavian artery between the two groups(P>0.05).②The CT number in experimental group was higher than that in control group (P<0.05).③The grading score of venous artifacts in control group was significantly higher than that in experimental group (P<0.05).④The radiation dose and the contrast medium vol-ume in experimental group was significantly lower than that in control group(P<0.05).Conclusion The applica-tion of 128-slice CT scanner withlow-dose radiation and low volume contrast medium protocol for cerebral and carotid CTA can result in high quality images.
出处 《中国临床保健杂志》 CAS 2013年第6期591-593,679,共4页 Chinese Journal of Clinical Healthcare
关键词 体层摄影术 螺旋计算机 脑血管造影术 辐射剂量 Tomography,spiral computed Cerebral angiography Radiation dosage
  • 相关文献

参考文献11

  • 1Lell MM,Anders K,Under M. New techniques in CT angiography[J].Radiographics:A Review Publication of the Radiological Society of North America,Inc,2006,(suppl 1):45-62.
  • 2黄锡恩,杨烈,何宏伟,康江河,段少银.头颈64层螺旋CT血管减影成像及临床应用[J].临床放射学杂志,2010,29(3):391-394. 被引量:12
  • 3Heverhagen JT,Bourekas E,Sammet S. Time-of-flight magnetic resonance angiography at 7 Tesla[J].In-vest Radiol,2008,(08):568-573.
  • 4Bueltmann E,eRB G,Kirhin MA. Intra-individual crossover comparison of gadobenate dimeglumine and ga-dopentetate dimeglumine for contrast-enhanced magnetic resonance angiography of the supraortic vessels at 3 Tesla[J].Investigative Radiology,2008,(10):695-702.doi:10.1097/RLI.0b013e31817d1505.
  • 5范亦辉,吕传国,顾卫,郁冬梅,顾庆春.三维增强磁共振血管成像诊断头颈部血管病变130例[J].南通大学学报(医学版),2008,28(3):201-202. 被引量:9
  • 6Almandoz JD,Javier MR,Pomerantz SR. Computed tomograghy angiography if the carotid and cerebral circu-lation[J].Radiologic Clinics of North America,2010,(02):265-281.
  • 7胡伟,任明山,刘新峰.内膜钙化对64层CT血管造影诊断颈动脉狭窄的影响[J].中国临床保健杂志,2011,14(3):237-240. 被引量:4
  • 8豆亚静,陈晖,严松彪.对比剂肾病的研究进展[J].中华临床医师杂志(电子版),2012,6(7):95-97. 被引量:27
  • 9李月卿.医学影像成像理论[M]北京:人民卫生出版社,201029-32.
  • 10Chang KJ,Caovan DB,Grand DJ. Reducing radiation dose at CT colonography:decreasing tube voltage to 100 kVp[J].Radiology,2013,(03):791-800.

二级参考文献40

共引文献81

同被引文献28

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;