摘要
详细探讨产生分流误差的主要因素:铠装热电偶的直径、种类、使用温度、中间部位加热带长 度、绝缘物种类及状态等,对分流误差的影响及其对策。其结论可供铠装热电偶的正确合理使 用及生产制造者参考。
The main factors causing shunting error are investigated in detail: the influence and countermeasures of armored thermocouple, suh as diameter, sort, operation temperature, middle heat length and sort of insulator. The conclusion can be consulted by the users and producers of armored thermocouple.
出处
《仪器仪表标准化与计量》
2004年第4期29-31,共3页
Instrument Standardization & Metrology
关键词
铠装热电偶
分流误差
绝缘电阻
漏电电流
Armored Thermocouple Shunting Error Insulation Resistance Leakage Current