摘要
提出了设计磁刺激器一般原则,包括基本理论、硬件及其构成,分析磁刺激器的RLC模型,给出模型参数的计算方法,讨论了决定磁场强度的各种因素;设计制作了一套磁刺激系统,绕制了圆形线圈和8字形线圈,并用这2种线圈进行实验,用特斯拉计检测线圈产生的磁场;实验数据显示,这2种线圈的磁场分布和目前已有的研究方法所作的理论计算对照,是相吻合的。在此基础上,进行了一个测量头部磁场的模拟实验。
This paper introduces general guidelines for designing and constructing a magnetic stimulator (MS). These guidelines cover the theoretical concepts, hardware aspects and necessary components. RLC model producing the impulses in MS is focused on and the way to calculate the parameters of the model is presented. Some factors that influence induced magnetic field are discussed. Experiments are carried through with self-developed round coil and 8-shaped, and Tesla meter is used to detect the magnetic fields. The experiments data show that the distribution of the induced magnetic fields by the two coils are tailored to those of theoretical calculation adopted now. A simulation experiment to measure magnetic field in brain has been completed.
出处
《医疗卫生装备》
CAS
2004年第8期3-5,共3页
Chinese Medical Equipment Journal
关键词
磁刺激
脉冲磁场
线圈
感应电场
magnetic stimulation
pulsed magnetic field
coil
induced electrical field