期刊文献+

肾小球滤过率测定及因子分析在肾动态显像中的应用 被引量:1

Measurement of glomerular filtration rate and the use of factor analysis in renal dynamic imaging
在线阅读 下载PDF
导出
摘要 对75例受检者进行^(99m)Tc-DTPA肾动态显像,其中23例进行肌酐清除率测定,31例进行抽血两样本肾小球滤过率(GFR)测定,发现肾动态显像测定GFR与两种传统方法相关很好(r>0.8,p<0.0001)。用因子分析方法对图像进行处理,有助于对肾功能图像的分析和诊断。 99mTc-DTPA renal dynamic imaging were performed in 75 patients to measure glomerular filtration rate(GFR), among them creatinine clearance rate(Ccr) was also measured in 23 and two blood sample method was measured in 31. The result showed that GFR has a good correlation with Ccr(r= 0.8326, p< 0.0001) and two blood sample method(r=0.8436,p<0.0001). Also use of factor analysis for image processing have further improved the image quality.
出处 《核技术》 CAS CSCD 北大核心 1993年第11期679-682,共4页 Nuclear Techniques
关键词 肾功能试验 因子分析 锝99M Measurement of glomerular filtration rate Test of kidney function Factor analysis Renal dynamic imaging Renal nuclide imaging 99mTc-DTPA