摘要 目的 :对单焦点和多焦点人工晶状体植入术后的拟调节力进行比较。方法 :选取合适的老年性白内障患者 ,分为两组。Ⅰ组 :30例 32只眼 ,植入AllerganArraySA 4 0NBTM多焦点人工晶状体 ,平均随访时间为 9.4个月。Ⅱ组 :30例 32只眼 ,植入AllerganSI4 0单焦点人工晶状体 ,平均随访时间为 15 .7月。所有病例均由同一眼科医师行标准超声乳化白内障摘除术联合人工晶状体植入术。术后采用试镜片法测试拟调节力。结果 :Ⅰ组 (MIOL)视远拟调节力为(2 .79± 0 .86 )D ,视近拟调节力为 (3.6 4± 1.0 3)D ;Ⅱ组(SIOL)视远拟调节力为 (0 .75± 0 .38)D ,视近拟调节力为 (1.0 6± 0 .4 2 )D ,两组差异有非常显著性 (P <0 .0 1)。结论 :多焦点人工晶状体可以使患者在术后获得较大范围的拟调节力 ,使人工晶状体的作用更接近于生理性晶状体。 Objective:To investigate pseudoaccommodation between the multiple focus intraocular lens(MIOL) implantation and single focus intraocular lens(SIOL) implantation.Methods:Sixty elderly cataract patients were enrolled and divided into two groups. Group Ⅰ:30 cases(32 eyes) were implanted with Allergan Array SA-40NB TM MIOL. The average follow-up visit was 9.4 months. Group Ⅱ:30 cases(32 eyes) were implanted with Allergan SI40 single focus intraocular lens(SIOL). The average follow-up visit was 15.7 months. All surgical procedure underwent standard phacoemulsification by the same ophthalmologist. Distance and near pseudoaccommodation were measured by the method of negative lenses.Results:Group Ⅰ(MIOL):distant pseudoaccommodation was an average of (2.79±0.86)D,and near was (3.64±1.03)D,P<0.01;group Ⅱ(SIOL):distant pseudoaccommodation was an average of (0.75±0.38)D,and near was (1.06±0.42)D,P<0.01.Conclusion:MIOL can provide a wide range of pseudoaccommodation for the patient.[
出处 《眼视光学杂志》 2004年第3期179-181,共3页 Chinese Journal of Optometry & Ophthalmology
关键词 调节力 术后 多焦点人工晶状体 单焦点人工晶状体植入 随访时间 患者 植入术 结论 显著性 目的 single focus intraocular lens/surgery multiple focus intraocular lens/surgery pseudoaccommodation
  • 相关文献

参考文献10

  • 1马显力,刘奕志,周灵,郭建兵,周妙芬.新型折叠式多焦点人工晶体临床应用观察[J].中国实用眼科杂志,2001,19(8):617-619. 被引量:8
  • 2高岩,张尧贞.衍射多焦人工晶体的临床应用[J].中华眼科杂志,1993,29(1):30-32. 被引量:6
  • 3Slagsvold JE.3M diffractive multifocal intraocular lens:Eight year follow-up[J].J Cataract Refract Surg,2000,26(3):402-407.
  • 4Brydon KW.AMO Array multifocal lens wersus monofocal correction in cataract surgery[J].J Cataract Refract Surg,2000,26(1):97-100.
  • 5Negishi K.Evaluation of a zonal progressive multifocal intraocular lens[J].Am J Ophthalmol,1997,124(3):321-330.
  • 6Steinert RF.A prospective comparative study of the AMO Array zonal progressive multifocal silicone intraocular lens and a monofocal intraocuar lens[J].Ophthalmology,1999,106(7):1243-1255.
  • 7Javit JC.Outcomes of cataract extraction with multifocal intraocular lens implantation[J].Ophthalmology,1997,104(4):589-599.
  • 8高岩.Array多焦点人工晶体临床应用及注意事项[J].中国实用眼科杂志,2002,20(6):409-411. 被引量:11
  • 9Bellucci R,Giardini P.Pseudoaccmmodation with the 3M diffractive multifocal intraocular lesa:A refraction study of 52 subjects[J].J Cataract Refractive Surg,1993,19(1):32-35.
  • 10Weghaupt H.Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lens[J].J Cataract Refract Surg,1998,24(5):663-665.

二级参考文献7

  • 1高岩,张尧贞.衍射多焦人工晶体的临床应用[J].中华眼科杂志,1993,29(1):30-32. 被引量:6
  • 2洪荣照 吴护平.超声乳化白内障手术学[M].厦门大学出版社,.100.
  • 3高岩,实用眼科杂志,1991年,9卷,196页
  • 4高岩,国外医学眼科学分册,1990年,14卷,337页
  • 5Javitt J C,Ophthalmology,1997年,104卷,589页
  • 6洪荣照,超声乳化白内障手术学
  • 7高岩,张尧贞.多焦人工晶体[J].实用眼科杂志,1991,9(4):196-201. 被引量:1

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部