期刊文献+

R-22的替代现状 被引量:13

R-22 REPLACEMENT STATUS
在线阅读 下载PDF
导出
摘要 The next step in the transition to environmentally safer refrigerants is phaseout of R-22. It is the most widely used refrigerant, both in the United Statess and on a global basis. Its application range in residential, commercial, industrial, and transport systems is broader than for any other refrigerant and spans cooling capacities from 2 kW to 33 MW(1/2 to 9,500 refrigeration tons, RT). The specific replacements depend on the applications. The next step in the transition to environmentally safer refrigerants is phaseout of R-22. It is the most widely used refrigerant, both in the United Statess and on a global basis. Its application range in residential, commercial, industrial, and transport systems is broader than for any other refrigerant and spans cooling capacities from 2 kW to 33 MW(1/2 to 9,500 refrigeration tons, RT). The specific replacements depend on the applications.
出处 《制冷与空调》 2005年第1期62-69,共8页 Refrigeration and Air-Conditioning
  • 相关文献

参考文献18

  • 1Minor ,B. H. 2004. "R410A and R407C Design and Performance- A Literature Review, "Proceedings of the Earth Technologies Forum. Arlington VA: Alliance for Responsible Atmospheric Policy.
  • 2Payne,W. V. ,and Domanski ,P. A. 2002. "A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures. "Proceedings of the 9th International Refrigeration Conference at Purdue paper R2 - 1. West Lafayette, IN:Purdue University.
  • 3Spatz, M. W. , and S. f. Yana Motta. 2003. "An Evaluation of Options for Replacing HCFC- 22 in Commercial Refrigeration Systems. "Proceedings of the International Congress of Refrigeration paper ICR0510. Paris, France: International Institute of Refrigeration.
  • 4WMO. 2003. Scientific Assessment of Ozone Depletion: 2002, report 47. Geneva, Switzerland: World Meteorological Organization(WMO) Global Ozone and Research Monitoring Project. Nairobi, Kenya:United Nations Environment Program(UNEP).Washington,DC,USA:National Oceanic and Atmospheric Administration(NOAA). Washington,DC, USA: National Aeronautics and Space Administration(NASA) Office of Earth Science. Brussels ,Belgium:European Commission, Reseaarch Directorate General. Chaired by A- L. N. Ajavon, D. L. Albritton, G. M~gie and R. T. Watson.
  • 5UNEP. 1987 with subsequent amendments. Montreal Protocol on Substances that Deplete the Ozone Layer. Nairobi, Kenya:United Nations Environment Programme(UNEP).
  • 6UNEP. 2003a. Handbook for the International Treaties for the Protection of the Ozone Layer(sixth edition). Nairobi, Kenya:UNEP Ozone Secretariat.
  • 7UNEP. 2003b. 2003 Report of the Refrigeration, Air - Conditioning and Heat Pumps Technical Options Committee - 2002 Assessment, United Nations Environment Programme(UNEP), Nairobi ,Kenya,January 2003.
  • 8Yoshida Y. , M. Funakura, N. Okaza, and M. Matsuo. 1999. "Residential Use Air Conditioner for Advanced COP :Acceptability of I-IFC- 32/I-Iydrocarbon Mixtures. "Heat Pumps-a Benefit for the Environment (proceedings of the Sixth IEA Heat Pump Conference). Frankfurt am Main, Germany: VWEW - Verlag.
  • 9ARI. 1998. Standard for Water Chilling Packages Using the Vapr- Compression Cycle(Standard 550/590 - 1998). Arlington, VA: Air- Conditioning and Refrigeration Institute.
  • 10ARI. 2003. Standard for Unitary Air- Conditioning And Air - Source Heat Pump Equipment(Standard 210/240 - 2003).Arlington, VA: Air - Conditioning and Refrigeration Institute.