摘要
论述了基于线路与断路器的关联矩阵计算变电站电气主接线可靠性指标的方法,介绍了该方法在3种典型电气主接线("单母分段接线"、"双母线带旁路接线"和"一个半断路接线")可靠性计算中的应用,结果能满足实际需要。
In this paper we proposed the method based on the element connection matrix of line and circuit to calculate the reliability induces.Also three typical examples are given for single-bus subsection configuration double-bus with auxiliary bus configuration and one and half breaker configuration.The calculating result can be used in the work.
出处
《山西电力》
2005年第2期6-8,23,共4页
Shanxi Electric Power