成人正视眼前房的形态测量及分析 被引量:6

The anterior chamber biometric measurements of the adult emmetropia
在线阅读 下载PDF
导出
摘要 目的 探讨Orbcan 系统在眼前房形态测量中的应用。方法 30例(6 0只眼)正视眼成人,对其用Orbcan 系统测量前房角、前房基底径,将测量的结果进行分析。结果 前房角的均值为4 9.348°±4 .798°;上方前房角最窄,下方前房角最宽,上半部前房角比下半部前房角要窄;颞侧前房角稍窄于鼻侧前房角但无统计学意义。前房基底水平径线、前房基底4 5°径线、前房基底垂直径线、前房基底135°径线的均值分别为(10 .86 8±0 .5 1) m m、(10 .914±0 .5 4 1) mm、(11.0 0 2±0 .5 9) mm、(10 .96 4±0 .5 2 5 ) mm ;四组间差异均无显著性(P >0 .0 5 )。结论 Or-bcan 在测量前房角、前房基底径方面具有应用价值。 Objective To evaluate the clinical application of the Orbscan tomographyⅡ system in measuring anterior chamber.Methods Each of the 60 eyes of 30 emmetropic adults was underwent the eight groups iridocorneal angle and the four anterior chamber fundus dimentions measurements with Orbscan tomography system . The data were anlalyzed by SPSS-10.0 statistical software.Results The iridocorneal angle was 49.348°±4.798. In the eight groups iridocorneal angle, the superior was the narrowest , while the inferior was the widest . The superior part of iridocorneal angle was narrower than the inferior part of iridocorneal angle. The temporal iridocorneal angle was narrower than the nasal, but it showes no significant differences. The anterior chamber fundus dimensions of horizontal, 45°, vertical and 135° were (10.868±0.51)mm,(10.914±0.541) mm,(11.002±0.59)mm, (10.964±0.525) mm, respectively.There were no significant differences among four anterior chamber fundus dimentions(P>0.05).Conclusion The Orbscan tomographyⅡ system is a good instrument in detecting iridocorneal angle and anterior chamber fundus dimentions.
出处 《临床眼科杂志》 2005年第2期99-102,共4页 Journal of Clinical Ophthalmology
关键词 正视 眼前房 形态测量 前房基底径 OrbcanⅡ系统 Orbscan tomography Ⅱ system The iridocorneal angle The anterior chamber fundus dimention
  • 相关文献

参考文献6

  • 1杨文利,刘磊,李雪非,王景昭.超声生物显微镜测量正常人眼前节结构的初步研究[J].中华眼科杂志,1997,33(2):85-87. 被引量:30
  • 2Yaylali V,Kaufman SC,Thompson HW. Corneal thickness measurements with the Orbscan Topography System and Ultrasonic pachymetry. J Cataract Refract Surg, 1997 ,23:1345.
  • 3杜之渝,郑晴,张大勇,陈曜,郭红,尹宏民.Orbscan系统与A超测量角膜厚度及前房深度比较[J].眼科,2002,11(4):229-231. 被引量:9
  • 4Charles J,Pavlin MD,Kasin Harasie Wicz,et al. Ultrasound biomicroscopy of anteriror segment structures in normal and glaucomatous eyes. Am J Ophthalmol,1992,113:381-389.
  • 5Allouch C, Touzeau O, Borderie V,et al. Orbscan: a new device for iridocorneal angle measurement. J Fr Ophtalmol,2002 ,25:799-806.
  • 6黄钰森 姚瞻 周增超.眼前节分析系统检查中国人正常房角宽度和前房深度[M].中国实用眼科杂志,2002.20,473.

二级参考文献3

共引文献37

同被引文献62

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部