摘要 提出了生物接触氧化法处理酒店废水经常出现的污泥上浮、接触氧化池滋生藻类、出水水质不稳定等问题,并讨论了相应的解决措施。经过实践证明,在容积负荷小于1.0kgBOD/(m3·d),并且原水水质和水量变化不大的情况下,生物接触氧化法能有效去除酒店废水中的化学需氧量、合成洗涤剂、油等污染物质,从而使出水水质达到国家相应的排放标准。 In this article, it proposed the conventional problems such as floating sludge, breeding algae and unstabilization of water quality,discussed the means to solve these problems. The practice proved:when volume loading is smaller than 1.0 kg BOD/(m^3·d), and the quality of original water do not change much, such polluter as chemical oxygen demand, synthetic detergent, oil, etc can be get rid of with biological contact oxidation. Thus the output water quality can meet country's corresponding discharge standard.
作者 黄向阳 彭峰
出处 《应用化工》 CAS CSCD 2005年第5期315-316,共2页 Applied Chemical Industry
关键词 酒店废水 生物接触氧化法 探讨 hotel waste water biological contact oxidation process discuss