阴离子树脂-活性炭分离富集等离子体发射光谱法测定富钴锰结壳中的痕量金银铂钯 被引量:23

Determination of Au,Ag,Pt and Pd in Co-rich Mn-crust Samples by ICP-AES after Preconcentration Using Anion-exchange Resin and Activated Carbon
在线阅读 下载PDF
导出
摘要 采用717阴离子树脂活性炭联合交换分离富集技术,电感耦合等离子体发射光谱法同时测定富钴锰结壳中痕量金、银、铂、钯.方法检出限四元素分别为:Au 1.3、Ag 0.4、Pd 0.6、Pt 4.8 ng/g.样品加标回收率在89.0%~110.3%,相对标准偏差3.5%~7.8%(n=4).方法已用于富钴锰结壳中痕量金银铂钯的测定. A method for determination of Au,Ag,Pt and Pd in Co -r ich Mn-crust samples by ICP-AES was studied. A combined preconcentration metho d using anion-exchange resin and activated carbon was used. The detection limit s (ng/g) of Au, Ag, Pd, and Pt are 1.3, 0.4, 0.6 and 4.8,respectively. The recov eries with standard addition for Au,Ag,Pt and Pd range from 89.0%~110.3% with precision of 3.5%~7.8% RSD(n=4). The method shows advantages of high accura cy, simple and convenient operation. The method has been applied to the determi nation of Au,Ag,Pt and Pd in Co-rich Mn-crust samples with satisfactory resu lts.
出处 《岩矿测试》 CAS CSCD 2005年第2期141-144,共4页 Rock and Mineral Analysis
关键词 富钴锰结壳 阴离子树脂 活性炭 电感耦合等离子体发射光谱法 铂钯 金银 分离富集技术 相对标准偏差 方法检出限 加标回收率 同时测定 痕量金 四元素 样品 gold silver platinum palladium rich-cobalt mangan ese crust anion-exchange resin activated carbon inductively coupled plasma atomic emission spectrometry(ICP-AES)