两种钛种植体骨界面SEM观察和电子探针元素分析 被引量:2

The scanning electron microscope ( SEM) observation and elementary analysis using electron probe of bone implant interfaces of two kinds of titanium implants in vitro
在线阅读 下载PDF
导出
摘要 目的:研究钛种植体的两种表面形态与其骨结合界面的关系。方法:在猴下颌磨牙区分期分别植入CDIC和ITI-TPS钛种植体,对界面进行光镜、扫描电镜观察和电子探针元素分析。结果:光镜和扫描电镜观察,种植后1个月的界面只有少量的骨形成;1~3个月的ITI-TPS种植界面的骨形成较CDIC者明显;种植后1年,二者未见明显差别。元素分析,界面钛、钙、磷相互渗透,各期ITI-TPS界面钛的渗透密度均较相应时期CDIC者高。结论:埋植后1~3个月,ITI-TPS种植体骨整合性优于CDIC种植体,但随时间的延长,两种种植体均可形成良好的骨性结合界面。ITI-TPS种植体渗透至界面周围组织的钛离子多于CDIC种植体者。 Objective: To evaluate the relation between the bone implant interfaces and the different surfaces of two types of implants. Methods: CDIC and ITI titanium implants were selected and implanted into the regions of mandibular posterior molars of rhesus monkeys. The boneimplant interfaces were evaluated respectively by light microscope, scanning electron microscope (SEM) and electron probe. Results: Little new bone was observed around the implants after one-month placement by light microscope and SEM. More bone growth around ITI implants was observed than that around CDIC implants except in the interfaces of one-year. Ions of Ti, P, Ca filtered into each other, and the density of Ti filtered from ITI implants in different time was respectively higher than that from CDIC implants. Conclusions: The osseointegration of ITI implants is better than that of CDIC implants three months after implantation, The interfaces bone formation between ITI and CDIC implants after one year has no significant difference. The phenomena of Ti filtered from ITI implants are more apparent than that from CDIC implants.
出处 《口腔颌面修复学杂志》 2005年第3期176-178,共3页 Chinese Journal of Prosthodontics
关键词 种植体 骨整合 扫描电子显微镜检查 电子探针 titanium implant body osseointegration scanning electron microscopy(SEM) electron probe
  • 相关文献

参考文献11

  • 1Batzer R, Liu Y, Cochran DL, et al. Prostaglandins mediate the effects of titanium surface roughness on MG63 osteoblast-like cells and alter cell responsiveness to 1 alpha,25-(OH)2D3[J]. J Biomed Mater Res, 1998, 41 (3):489~496
  • 2Lincks J, Boyan BD, Blanchard CR, et al. Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition [J].Biomaterials, 1998, 19 (23): 2219~2232
  • 3宋光保,薛淼,宁丽.TM种植体的表面特征与骨整合[J].口腔材料器械杂志,2000,9(3):134-137. 被引量:15
  • 4Kawahara D, Ong JL, Raikar GN, et al. Surface characteri zation of radiofrequency glow-discharged and autocla ved titanium before and after simulated biological fluid exposure[J]. Iuter J Oral Implant, 1996, 11 (4) :435 ~ 442
  • 5Legeros RZ, Craig RG. Strategies to affect bone remodeling:osteointegration[J]. J Bone Miner Res, 1993, 8 (2):583~596
  • 6Geraledo Gionvanni, Lugero Ms, Guzzo ML, et al.Histomorphometric Evaluation of Titanium Implants in Osteoporotic Rabbits [J]. Implant Dentistry, 2000, 9 (4):303~309
  • 7Lin DG, Kenny DJ, Lekic P. Storage conditions of avulsed teeth effect the pheno type of cultured human periodontal ligament cells[J]. J Periodont Res, 2000, 35 (1):116
  • 8Okazak Y, Nishimura E, Nakada H, et al. Surface analysis of Ti-15Zr-4Nb-4Ta alloy after implantation in rat tibia[J].Biomaterials, Mar, 2001,22 (6): 599~607
  • 9丁仲鹃,董强,肖旭辉,董宝财,王静,梁星.两种钛种植体与骨结合界面的组织学研究[J].华西口腔医学杂志,2004,22(3):242-245. 被引量:9
  • 10李家驹.岛津最新型电子探针EPMA-1600简介[J].现代科学仪器,1997,14(1):54-55. 被引量:1

二级参考文献22

  • 1[1]sergo V, Sbalzero O, David RC, Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyaptite coatings[J]. Biom-aterials, 1997, 18(6):477-482.
  • 2[3]Han CH. Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants [J]. Clin Oral Implants Res,1998,9(1):1-10.
  • 3[4]Perry R. Paul Jonhnson Soheila Dadgostari, Early endosseous integration enhanced by dual acid etching of titanium: a torque removal study in the rabbit[J]. Clin Oral Impants Res, 2001,12(2) :350-359.
  • 4[5]Branemark PI. Tissue Intergrated Protheses: Osseointergration in Clinical Dentaistry[M]. Quintessence Publishing Co, Inc. 1985:99-116.
  • 5[6]Geraledo G, Lugero M, Falco Caparbo V, et al. Histomorphometric evaluation of titanium implants in osteoporotic rabbits [J]. Implant Dent,2000, 9(4) :303-309.
  • 6[7]Craig RG, Le Geres RZ. Early events associated with periodontal conJ Biomed Mater Res, 1999,47(4):585-594.
  • 7[8]Baier RE, Meyer AE. Implant surface preparation[J]. Int J Oral Maxillofac Implants, 1998,13 ( 1 ): 9-20.
  • 8[10]Buser SS. Oral implantology: Basic, ITI Hollow Cylinder System[M].Thieme Medical Publishers. Inc. New York, 1996,83: 368-369.
  • 9Gross KA, Berndt CC, Goldschlag DD, et al. In vitro changes of hydroxyapatite coatings. Int J Oral Maxillofac Implants. 1997;12:509.
  • 10Steflik DE, Corpe SC, Lake FT, et al. Composite morphology of the bone and associated support tissue interfaces to osseointegrated dental implants;TEM and HVEM analyses .Int J Oral Maxillofac Implants, 1997,12: 443.

共引文献20

同被引文献27

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部