摘要 基于在甲醛的作用下,高锰酸钾对甲氧氯普胺的氧化作用而产生化学发光的现象,建立了一种新的用流动注射-化学发光法测定甲氧氯普胺含量的方法.该方法测定甲氧氯普胺的线性范围为0.2~100 mg/L,检出限为0.1 mg/L.对于8 mg/L的甲氧氯普胺标准溶液连续11次测定的相对偏差为1.2%.该方法可用于对制药废水、片剂和针剂中甲氧氯普胺含量的测定. A new method for the determination of metoclopramide by flow injection chemiluminescence reaction is proposed. It is based on chemiluminescence produced by the oxidation of metoclopramide with potassium permanganate in the presence of formaldehyde. The linear range for the determination of metoclopramide is 0.2 - 100 mg/L and the detection limit is 0. 1mg/L. The RSD is 1.2 % for 11 measurements of 8 mg/L metoclopramide standard solution. The method can be used for the determination of metoclopramide in pharmaceutical waste water, tablets and injections.
出处 《化学研究》 CAS 2005年第3期87-89,共3页 Chemical Research
关键词 高锰酸钾 甲醛 化学发光 甲氧氯普胺 流动注射 potassium permanganate formaldehyde chemiluminescence metoclopramide flow-injection
  • 相关文献

参考文献9

  • 1Abdet-Gawad F M, EI-Guindi N M. Spectrophotometric determination of metoclopramide and oxybuprocaine through ion pair formation with thiocyanate and molybdenum (Ⅴ) or cobalt ( Ⅱ )[J]. Anal Lett, 1995, 28(8) : 1437 -1447.
  • 2Abdei B A, Foda N H, Tayel S, et al. Devetopment and application of a spectrophotometric method for the qunntitation of metoclopramide in urine[J]. Egypt J Pharm Sci, 1988, 29(1 -4) : 493 -506.
  • 3Buna M, Aaron J J, Prognon P, et al. Effect of pft and solvent on the fluorescence properties of biomedically important benzamides. Application to determination in drugs and in human urine[J]. Analyst, 1996. 121 ( 11 ) : 1551 - 1556.
  • 4Rao H L, Aroor A R, Rao P G. Fluorimetric estimation of metoclopramide [ hydrrchloride] in dosage forms[J]. Indian Drugs,1991 , 28(4) : 195 - 196.
  • 5Badaway S S, Shoukry A F, lssa Y M. Ion-selective electrode tor the determination of metoclopramide[J]. Analyst, 1986, 111 :1363 - 1365.
  • 6Diaz C, Vidal J C, Galban J, et al. Potentimetric determination of metoclopramide using a double-membrane-based ion-selective electrode[ J ]. J Electroanal Chem Interfac Electrochem, 1989, 258 (2) : 295 - 302.
  • 7Agater I B, Jewsbury R A. Direct chemiluminescence determination of ascorbie acid using flow injection analysis[J].Anal Chim Acta, 1998, 356(3): 289-294.
  • 8Deftereos N T, Calokerinos A C, Efstathiou C E. Flow injection chemiluminometric determination of epinephrine, norepinephrine,doparnine and L-dopa[J].Analyst 1993, 118(6):627-632.
  • 9Slawinska D, Slawinskl J. Chemiluminescence flow method for determination of formaldehyde[J]. Anal Chem, 1975, 47( 13):2101 -2109.

同被引文献58

引证文献2

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部