1021t/h锅炉敷设卫燃带探析 被引量:7

Attaching a Refractory Belt to a 1021t/h Boiler
在线阅读 下载PDF
导出
摘要 石门电厂1 021 t/h锅炉原设计无卫燃带,根据实际燃煤和低负荷运行、调峰情况,运用燃煤着火燃烧的基本原理,在火嘴边适当部位敷设一种块状拼集凹形卫燃带,改善着火燃烧条件,使锅炉满足了实际燃煤和调峰运行的需要。 Shimen Power Plant's 1 021t/h boiler was originally designed without a refractory belt. Considering the coal used and requirements at low load, as well as those of cyclic operation, a refractory belt of protruding shape, composed of assembled bricks, was attached in accordance with the fundamental principles of coal ignition and combustion, for the purpose of improving conditions of ignition, enabling the boiler to burn the coal actually used and especially to meet requirements of cycling.
作者 刘建国
机构地区 湖南省石门电厂
出处 《发电设备》 2005年第6期361-364,共4页 Power Equipment
关键词 锅炉 卫燃带 煤粉着火 boiler refractory belt pulverized coal ignition
  • 相关文献

参考文献5

  • 1陈学俊 陈听宽.锅炉原理[M].北京:机械工业出版社,1983..
  • 2哈尔滨锅炉厂.HG-1021/18。2-540/540-WM10型锅炉设计说明书及图纸[Z].哈尔滨锅炉厂,1994..
  • 3刘建国.石门电厂2×300MW锅炉敷设卫燃带技术方案[R].石门电厂,2001..
  • 4郭永浩.四角燃烧无烟煤锅炉低负荷稳燃技术[J].中国电力,2000,33(11):21-24. 被引量:5
  • 5陈冬林.基于可调卫燃带的燃煤锅炉燃烧稳定性分析[C]..湖南省动力工程学会2002~2003年学术年会论文集[C].,2003-4..

二级参考文献3

  • 1聂剑平.焦作万方电力有限公司No1炉燃烧调整试验报告[M].电力部热工研究院,1998..
  • 2孙学信 丘纪华.焦作万方电力有限公司1号炉燃烧器改造试验报告[M].华中理工大学煤燃烧国家重点实验室,1999..
  • 3孙学信.焦作爱依斯万方电力有限公司一号炉燃烧器改造技术方案和改后效益分析[M].华中理工大学煤燃烧国家重点实验室,..