摘要
建立救急行军制剂中的硫化汞含量测定方法。采用络合滴定法测定。硫化汞的平均回收率98.12%;RSD为1.02%(n=10)。本法操作简便,结果准确。
The complexometric titration method was established for the determination of mercury sulfide in March Preparations for Emergency treatment (Jiuji Xingjun Zhiji). The average recovery of mercury sulfide was 98. 12% and RSD was 1.02% (n= 10). The method was simple, convenient and accurate.
出处
《中国药事》
CAS
2005年第11期669-670,共2页
Chinese Pharmaceutical Affairs
关键词
络合滴定法
硫化汞
含量
complexometic titration
mercury sulfide
content