基于动态模板匹配技术的放疗摆位误差测量 被引量:1

Positioning error measurement in radiotherapy based on dynamic template matching technique
在线阅读 下载PDF
导出
摘要 本文考虑到病人在放射治疗过程中身体发生变形而使得基于固定模板匹配方法测量重复摆位误差精度降低的问题,提出了基于动态模板匹配的放疗病人重复摆位方法。该方法是对基于CT重建数字射线图像(DRR)作为模板进行匹配的重复摆位技术的改进,将能反映病人体态变化的视频重建三维体表模型作为匹配的模板进行摆位误差的计算。理论研究和实际检验表明,采用动态视频模板匹配的摆位方法,可以在保证摆位精度的同时消除因病人身体变形带来的不利影响。 The decrease of accuracy in patients' repeated positioning in radiotherapy due to body's transformation is considered in this paper. It brings forward a new patients' repeated positioning technique based on dynamic template matching method. And it is an optimization of the matching method based on the CT digitally reconstructed radiograph (DRR), which uses the video reconstructed 3D surface model that can reflect the body's transformation as the matching template instead of DRR. This method is studied in theory and testified in practice, and it can not only guarantee the positioning accuracy but also eliminate the adverse influence brought by body's transformation.
出处 《中国医学影像技术》 CSCD 北大核心 2005年第12期1926-1929,共4页 Chinese Journal of Medical Imaging Technology
关键词 体态变形 固定模板 动态模板 三维体表模型 匹配 重复摆位 Body's transformation Fixed template Dynamic template Three-dimensional surface model Matching method Repeated positioning
  • 相关文献

参考文献16

  • 1Rudat V, Flentje M, Oetzel D, et al. Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy[J]. Radiother Oncol, 1994,33 (1): 56-63.
  • 2Rosenthal SA, Roach M 3rd, Goldsmith BJ, et al. Immobilization improves the reproducibility of patient positioning during six-field conformal radiation therapy for prostate carcinoma[J]. Int J Radiat Oncol Biol Phys, 1993,27(4) :921-926.
  • 3Greer PB, Mortensen TM, Jose CC. Comparison of two methods for anterior-posterior isocenter localization in pelvic radiotherapy using electronic portal imaging[J] . Int J Radiat Oncol Biol Phys,1998,41(5):1193 1199.
  • 4Mock U, Dieckmann K, Wolff U, et al. Portal imaging based definition of the planning target volume during pelvic irradiation for gynecological malignancies[J]. Int J Radiat Oncol Biol Phys, 1999,45(1) :227-232.
  • 5Stroom JC, Olofsen-van Acht MJ, Quint S, et al. On line set-up corrections during radiotherapy of patients with gynecologic tumors [J]. Int J Radiat Oncol Biol Phys, 2000,46(10) :499-506.
  • 6McParland BJ. Uncertainty analysis of field placement error measurements using digital portal and simulation image correlations[J].Med Phys, 1993,20(3) :679-685.
  • 7Menke M, Hirschfeld F, Mack T, et al. Photogrammetric accuracy measurements of head holder systems used for fractionated radiotherapy[J]. Int J Radiat Oncol Biol Phys, 1994, 29 (5):1147-1155.
  • 8Milliken BD, Rubin SJ, Hamilton RJ, et al. Performance of a video-image-subtraction-based patient positioning system[J]. Int J Radiat Oncol Biol Phys, 1997,38(4) :855-866.
  • 9Clippe S, Sarrut D, Malet C, et al. Patient setup error measurement using 3D intensity-based image registration techniques [J].Int J Radiat Oncol Biol Phys, 2003,56(1 ) :259-265.
  • 10Ploeger LS, Frenay M, Betgen A, et al. Application of video imaging for improvement of patient set-up [J]. Radiother Oncol,2003,68(3): 277-284.

二级参考文献2

共引文献6

同被引文献7

引证文献1

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部