期刊文献+

大锥度牙胶尖与两种镍钛机动根管预备锉的匹配性研究 被引量:5

Study of fitting of greater taper gutta percha cones in root canals prepared with two kinds of nickel-titanium rotary instruments
在线阅读 下载PDF
导出
摘要 目的评价大锥度牙胶尖与两种机动镍钛根管预备锉的匹配性。方法选择40只离体后牙根管,根据初尖锉的号码和近远中向根管弯曲度分为2组,分别以ProTaper和ProFile两种机动镍钛根管锉完成根管预备,插入大锥度牙胶尖进行试尖,比较两者的匹配性。结果ProTaper F1、F2、F3与0.06锥度/20、253、0号牙胶尖的匹配率分别为80%、88%、92%,均较同锥度大1号的牙胶尖匹配率高,差异有显著性(P<0.01)。ProFile 0.06锥度/30号和40号与0.04锥度同号牙胶尖的匹配率最高,分别为83%和96%,其次是0.06锥度小1号牙胶尖,而与0.06锥度同号牙胶尖匹配率最低,分别为35%和25%,3者间差异有显著性(P<0.01)。结论大锥度镍钛机动器械预备的根管,与主尖锉同号而锥度减小或锥度相同且小1号的大锥度牙胶尖有良好的匹配性。 Objective To evaluate the fitting of greater taper gutta pereha (GP) cones in root canals prepared with two kinds of nickel-titanium (niti) rotary instruments. Methods 40 canals of extracted posterior teeth were divided into two groups according to the size of initial apical file and the canal curvature in mesio-distal direction. The two groups were prepared with either ProTaper or ProFile niti rotary instruments, after which cone-fitting was cawied out by inserting the greater taper GP cones of different sizes/tapers into the prepared canal. Results In canals prepared to ProTaper F1, F2 and F3, the fitting rates of size 20, 25 and 30/0.06 taper GP cones were 80%, 88% and 92%, respectively, which were higher than those of GP cones with one size larger than the Protaper finishing files but of the same taper. The differences were statistically significant ( P 〈 0.01 ). In canals prepared to 0.06 taper ProFile size 30 and 40, the highest fitting rates were achieved with the same size/0.04 taper GP cones, which were 83% and 96%, respectively. The fitting rates with GP cones of one size smaller/0.06 taper ranked secondly, the lowest fitting rates came to the GP cones of the same size and same taper, which were 35% and 25%, respectively. The differences were statistically significant ( P 〈 0.01 ). Conclusion In canals prepared with greater taper niti rotary instruments, greater taper GP cones with same size/smaller taper or same taper/smaller size as compared with the master apical files fitted well as master GP cones.
出处 《口腔医学》 CAS 2005年第6期339-340,共2页 Stomatology
关键词 根管治疗 试尖 牙胶 镍钛机动根管预备锉 匹配性 root canal therapy cone-fitting gutta percha nickel-titanium rotary instruments Stomatology
  • 相关文献

参考文献6

二级参考文献13

  • 1凌均ぶ鞅.牙髓病学:第一版[M].北京:人民卫生出版社,1998.180.
  • 2Ruddle CJ. The ProTaper endodontie system: geometries, fealures, and guidelines for use[J]. Dent Today, 2001, 20(10):60-67.
  • 3Goerig AC, Michelich RJ, Schultz HH. Instrumentation of root canals in molar using the Step - down technique[ J ]. J Endod, 1982, 8(12) :550 - 554.
  • 4Negro MM. Effect of intmcanal use of nonsteroidal anti- inflammatory agents on posttreatment enodontic pain [ J ]. Oral Surg Oral Med Oral Pathol, 1994, 77(5):507-513.
  • 5Wei X, Cheung C-,S. Performance of three nickd - titanium instruments for prepating curved root canals to two different apical dimemions[J].Ofinese J of Dent Res, 2002, 5(1): 32-42.
  • 6Ruddle CJ. The ProTaper technique: endodontics made easier[J]. Dent Today, 2001, 20(11):58-68.
  • 7Bergmans L, Van Cleynenbreugel J, Wevers M, et al. Mechanical root canal preparation with NiTi rotary instruments: rationale, performnce and safety[J]. Status report for the American Journal of Dentistry, Am J Dent 2001, 14(5):324.
  • 8樊明文.口腔医学新进展:第2版[M].武汉:湖北科学技术出版社,2000.201-208.
  • 9岳松龄.口腔内科学:第2版[M].北京:人民卫生出版社,1987.242.
  • 10严华华.三种根充材料治疗慢性根尖周炎疗效比较[J].口腔医学纵横,1998,14(1):59-60. 被引量:15

共引文献162

同被引文献47

  • 1杨萍,耿发云,陈忠瑜,姚馨慧,包年香.试尖对根管充填质量影响的研究[J].现代预防医学,2005,32(6):690-691. 被引量:4
  • 2王红,黄霞,徐琼,刘昭慧.根管冠部预处理和不同锥度牙胶尖对根管充填后根尖部封闭性能的影响[J].牙体牙髓牙周病学杂志,2005,15(11):627-629. 被引量:6
  • 3范兵,边专,樊明文.牙体牙髓临床治疗Ⅱ. 根管预备的工作长度、宽度和锥度[J].中华口腔医学杂志,2006,41(3):184-187. 被引量:27
  • 4张富华,黄定明,谭红,高小洁,贾刘合,周学东.镍钛器械预备根管对根管充填根尖孔封闭性的影响[J].牙体牙髓牙周病学杂志,2006,16(11):630-633. 被引量:5
  • 5Wu MK,R'oris A,Barkis D,et al.Prevalence and extent of long oval canals in the apical third.Oral Surg Oral Med Oral Pathol Oral Radiol Endod,2000,89(6):739-743.
  • 6四川大学华西口腔医院牙体牙髓病科.根管治疗技术规范与疗效评价标准[A],2011435-437.
  • 7Deplazes P,Peters O,Barbakow F. Comparing apical prepara-tions of root canals shaped by nickel-titanium rotary instru-ments and nickel-titanium hand instruments[J].{H}Journal of Endodontics,2001,(3):196-202.
  • 8Nixdorf DR,Moana-Filho EJ,Law AS. Frequency of persistent tooth pain after root canal therapy:a systematic review and meta-analysis[J].{H}Journal of Endodontics,2010,(2):224-230.
  • 9El Batouty KM,Elmallah WE. Comparison of canal trans-portation and changes in canal curvature of two nickel-ti-tanium rotary instruments[J].{H}Journal of Endodontics,2011,(9):1290-1292.
  • 10Bernardes RA,Rocha EA,Duarte MA. Root canal area increase promoted by the EndoSequence and Pro-Taper systems:comparison by computed tomography[J].{H}Journal of Endodontics,2010,(7):1179-1182.

引证文献5

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部