电流互感器二次负载阻抗对电流互感器误差有较大的影响。为此,通过电流互感器等值电路和误差曲线,分析了电流互感器的二次负载特性,并讨论了电流互感器标准装置二次回路阻抗的测试原理和方法。
Secondary load impedance of a current transformer (CT) has great influence on the error of the CT. By use of the CT equivalent circuit and error curve, the secondary load characteristics of CT are analyzed. The principle and method for testing the impedance in the secondary circuit of CT standard calibrator units are discussed as well.