摘要
介绍了用活性炭提纯显色剂──4-氨基安替比林(4-AAP)的方法。提纯后的4-AAP用于水中挥发酚的测定,其检出限为0.17μg;用2μg苯酚进行精密度试验,RSD(n=6)为6.8%。各项参数均优于未提纯试剂的结果。
The purification of the color developing reagent 4-aminoantipyrine is effected by the use of active charcoal, and the determination of volatile phenol is obviously improved by the application of the purified reagent.A detection limit of 0. 17 μg is obtained. Tests are carried out with 2 μg phenol smaples,the recovery is 98% and the RSD(n=6) is 6. 8%.
出处
《岩矿测试》
CAS
CSCD
北大核心
1996年第1期65-67,共3页