期刊文献+

反渗透系统给水电导率与pH的系统影响 被引量:24

Influence of feedwater conductivity and pH value in RO systems
在线阅读 下载PDF
导出
摘要 测试并分析了一、二级反渗透系统给水电导率及pH与系统透盐率和浓淡水pH之间的关系。测定了给水pH在6~8、给水电导率在400~1000μS/cm范围内的系统透盐率较低,且pH为7.5、电导率为500μS/cm的系统透盐率最低。此测试与分析为反渗透技术提供了重要的运行与设计依据。 The relationships of feedwater conductivity and pH value with the system salt permeability and concentrated fresh water in the first and second grade RO systems are tested and analysed. When the pH value of feedwater is 6 to 8 and the feedwater conductivity is in the range of 400 to 1 000 μS/cm, the system salt permeability is rather low. When the pH value is 7.5 and the feedwater conductivity is 500 μS/cm, the system salt permeability is the lowest. These tests and analyses provide important running and design basis for RO technique.
出处 《工业水处理》 CAS CSCD 北大核心 2006年第3期62-64,共3页 Industrial Water Treatment
关键词 反渗透系统 系统透盐率 PH RO system system salt permeability pH value
  • 相关文献

参考文献1

  • 1时均 袁权.膜技术手册[M].北京:化学工业出版社,2001..

共引文献64

同被引文献159

引证文献24

二级引证文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部