期刊文献+

调强适形放射治疗的多学科整合

Integrated Platform of Therapeutic Decision-making in Intensity Modulated Radiation Therapy
在线阅读 下载PDF
导出
摘要 调强适形放射治疗是放射治疗100余年历史中的一个革命性进步,能使高剂量的立体分布适合外形非常不规则甚至怪异的肿瘤,调整靶区内诸点的输出剂量率,显著提高肿瘤放疗的疗效。近年计算机技术、放射物理学、放射生物学、分子生物学、影像学特别是功能性影像学的快速发展以及多门边缘学科之间的有机结合,为调强适形放射治疗提供在靶区三维精确模拟定位、立体定向定位摆位框架、逆向治疗计划系统、调强治疗机等方面的发展基础。调强适形放射治疗——多元化医学理论下的医疗方法将在学科交叉、综合发展中进一步巩固。 Intensity modulated radiation therapy is a revolutionary development during more than one century in radiation oncology. It makes threedimensional target field with high dose conform extremely irregular tumor and adjust exporting dose rate d every point in target field. This method can obviously increase therapeutic effect by radiation therapy. Newly rapid development and cross link of computing technique, radiation physics, radiation biology, molecular biology and imaging (especially functional imag- ing) provide a base for intensity modulated radiation therapy, including precise three dimensional simulation in target fieldt stereotaxis positioning framework, retro- treatment planning system and intensity modulated therapeutic machine. Intensity mcxtulated radiation therapy, which comes from cross - linking multiple subjects, is to consolidate all the more through multielemental approach and theory of medicine.
作者 王志震
出处 《医学与哲学(B)》 2006年第3期36-37,44,共3页 Medicine & Philosophy(B)
关键词 调强适形放射治疗 综合发展 多学科 intensity modulated radiation therapy, cross - link, multiple subjects
  • 相关文献

参考文献4

二级参考文献31

  • 1Zelefsky MJ,Fuks Z,Leibel SA.Intensity-modulated radiation therapy for prostate cancer[J].Semin Radiat Oncol,2002,12(3):229-237.
  • 2Butler EB,Teh BS,Grant WH 3rd,et al.Smart(simultaneous modulated accelerated radiation therapy)boost:a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy[J].Int J Radiat Oncol Biol Phys,1999,45(1):21-32.
  • 3Krueger EA,Fraass BA,Pierce LJ.Clinical aspects of intensitymodulated radiotherapy in the treatment of breast cancer[J].Semin Radiat Oncol,2002,12(3):250-259.
  • 4Jaffray DA,Yan D,Wong JW,et al.Managing geometric uncertainty in conformal intensity-modulated radiation therapy[J].Semin Radiat Oncol,1999,9(1):4-19.
  • 5Shimizu S,Shirato H,Ogura S,et al,Detection of lung tumor movement in real-time tumor-tracking radiotherapy[J].Int J Radiat Oncol Biol Phys,2001,51(2):304-310.
  • 6Hanley J,Debois MM,Mah D,et al,Deep inspiration breath-hold technique for lung tumors:the potential value of target immobilization and reduced lung density in dose escalation[J].Int J Radiat Oncol Biol Phys,1999,45(3):603-611.
  • 7Martinez AA,Yah D,Lockman D,et al.Improvement in dose escalation using the process of adaptive radiotherapy combined with threedimensional conformal or intensity-modulated beams for prostate cancer[J].Int J Radiat Oncol Biol Phys,2001,50(5):1226-1234.
  • 8Ploeger LS,Smitsmans MH,Gilhuijs KG,et al.A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device[J].Med Phys,2002,29(6):1071-1079.
  • 9Ling CC,Humm J,Larson S,et al.Towards multidimensional radiotherapy(MD-CRT):biological imaging and biological conformality[J].Int J Radiat Oncol Biol Phys,2000,47(3):551-560.
  • 10Chao KS,Bosch WR;Mutic S,et al.A novel approach to over come hypoxic tumor resistance:Cu-ATSM-guided intensity-modu-lated radiation therapy[J].Int J Radiat Oncol Biol Phys,2001,49(4):1171-1182.

共引文献27