期刊文献+

圆形截面组合柱-钢梁框架节点反复加载性能试验研究 被引量:4

Experimental study on the cyclic behavior of composite circular column-steel beam frame joints
原文传递
导出
摘要 本文以北京LG大厦塔楼为工程背景,采用6个大尺寸试件,对钢梁和钢骨混凝土圆柱组成的框架节点进行了低周反复加载试验。试件包括按“弱梁强柱强节点”设计和“强梁强柱弱节点”设计两种情况。前者发生梁铰型破坏,节点核心区始终基本完好,试件承载力由梁端承载力控制,延性和耗能均满足要求。后者虽发生节点核心区破坏,但其性能明显好于钢筋混凝土框架节点,能满足抗震基本要求;当轴压比从0.16提高到0.32时,节点核心区强度有所提高;在节点附设柱面承压板(FBP板)可提高承载力、延性和耗能能力。在钢骨上焊接栓钉的构造措施可避免粘结破坏。 6 large-sized specimens of circular-section steel minforeed concrete column-steel beam frame joints were tested under cyclic reversed loading. Two types of specimens, "weak beam-strong column-strong joint" and "strong beam-strong column-weak joint", were studied. For the former, the plastic hinge occurred at beam end, while the joint core had almost no damage. Load-carrying capacities of the specimens were controlled by flexural capacities of steel beams. Ductility and energydissipation ability were adequate for the seismic design. For the latter, failure happened within the joint core zone, but the behavior of the specimens was much better than that of the reinforced concrete frame joint and they can satisfy the demands of seismic design on the whole. As the axial compression ratio increased from 0.16 to 0.32, the capacities of the joints increased. By using the face beating plates on the joint, the load-carrying capacities, ductility, energy-dissipation abilities of the specimens increased. The use of shear studs on the steel could avoid the bond failure.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2006年第2期20-27,共8页 Journal of Building Structures
基金 北京市科委科技项目(953300801) 北京市规委科研项目(199802001)
关键词 钢-混凝土混合结构 钢骨混凝土 圆柱框架节点 抗震试验 steel-concrete hybrid structure steel reinforced concrete cireular-section column frame joint seismic test
  • 相关文献

参考文献6

  • 1梁柱节点专题组.劲性钢筋混凝土梁柱节点性能及受剪承载力[A].混凝土结构研究报告选集3[C].北京:中国建筑工业出版社,1994:502-518.
  • 2Tauqir M Sheikh,et al.Beam-column moment connections for composite frames:Part 1[J].Journal of Structural Engineering,ASCE,1989,115 (11):2858-2876.
  • 3Gregory G Deierlein,et al.Beam-column moment connections for composite frames:Part 2[J].Journal of Structural Engineering,ASCE,1989,115 (11):2877-2896.
  • 4ASCE Task Committee on Design Criteria for Composite Structures in Steel and Concrete.Guidelines for design of joints between steel and reinforced concrete columns[J].Journal of Structural Engineering,ASCE,1994,120 (8):2330-2357.
  • 5唐九如,陈雪红.劲性砼梁柱节点受力性能与抗剪强度[J].建筑结构学报,1990,11(4):28-36. 被引量:34
  • 6侯光瑜,陈彬磊,刘向阳,赵均,陈向东,田守瑞.圆形截面组合柱-钢梁框架节点受剪承载能力分析[J].建筑结构学报,2006,27(2):28-32. 被引量:4

二级参考文献16

  • 1赵均,田守瑞,邹景春,陈向东,侯光瑜,陈彬磊,刘向阳.圆形截面组合柱-钢梁框架节点反复加载性能试验研究[J].建筑结构学报,2006,27(2):20-27. 被引量:4
  • 2GB50011-2001.建筑抗震设计规范[S].[S].,..
  • 3陈雪红,1989年
  • 4唐九如,钢筋混凝土框架节点抗震,1989年
  • 5姜维山,西安冶金建筑工程学院学报,1986年,12期
  • 6唐九如,东南大学学报,1985年,10期
  • 7匿名著者,1978年
  • 8T M Sheikh,G G Deierlein,J A Yura,J O Jirsa.Beam-column moment connections for composite frames:part 1[J].Journal of Structural Engineering,1989,115(11):2858-2876.
  • 9G G Deierlein,T M Sheikh,J A Yura,J O Jirsa.Beam-column moment connections for composite frames:part 2[J].Journal of Structural Engineering,1989,115 (11):2877-2896.
  • 10薛伟辰.圆形截面钢筋混凝土节点抗震性能的试验研究[D].哈尔滨工业大学,1996.