摘要
基于多回路数学模型,对异步电动机定子绕组匝间短路故障瞬变过程做了数字仿真,并完成了相关物理实验。在此基础上,对定子绕组匝间短路故障的典型特征进行灵敏度与可靠性评定,遴选出定子负序视在阻抗低通滤波值这一可靠兼具良好灵敏度的定子绕组匝间短路故障特征,从而为定子绕组匝间短路故障的灵敏、可靠检测奠定了基础。
The transient numeric simulation and relevant experiments of stator winding inter-turn short circuit fault of asynchronous motor are conducted using multi-loop mathematic model. Based on the simulation and experimental results, the sensitivity and reliability of the typical fault features of stator winding inter-turn short circuit are evaluated. It is concluded that the low-pass-filtered stator negative sequence apparent impedance is the most robust and reliable fault feature.
出处
《华北电力大学学报(自然科学版)》
CAS
北大核心
2006年第3期22-26,40,共6页
Journal of North China Electric Power University:Natural Science Edition
基金
国家自然科学基金资助项目(50407016.)
关键词
异步电动机
多回路模型
数字仿真
定子绕组
匝间短路
故障特征
asynchronous motor
multi-loop model
numeric simulation
inter-turn short circuit ofstator winding
fault feature