期刊文献+

催化裂化装置烟机入口暖管膨胀节事故失效分析的有限元计算 被引量:2

Finite Element Computation for Accident Failure Analysis of Inlet Heating Pipe Expansion Joint of Flue Gas Turbine for CCU
在线阅读 下载PDF
导出
摘要 某石化公司100×104t/a两段提升管催化裂化装置烟机入口暖管一只DN300单式铰链型膨胀节,在生产运行过程中暖管水平段单式铰链型膨胀节波纹管突然发生爆裂,为分析失效事故原因,对失效的膨胀节进行了有限元计算与分析,并提出了改进措施。 In a petrochemical branch under PetroChina Group one DN300 single hinge type expansion joint of two heating pipes at flue gas turbine inlet of 100×10^4 t/a riser cracker abruptly burst at the bellows in its horizontal segrment during the production, in order to analyze the cause for the failure accident, finite element computation and analysis were conducted on the failed expansion joint and improvement actions were proposed in this paper.
出处 《压力容器》 北大核心 2006年第5期32-35,41,共5页 Pressure Vessel Technology
关键词 催化裂化装置 烟机暖管 膨胀节 失效分析 有限元计算 应力应变评定 CCU flue gas turbine heating coil expansion joint failure analysis finite element computation stress - strain assessment
  • 相关文献

参考文献4

  • 1马金华,蔡善祥,王冰.三旋出口主管线和暖机旁路管线及其膨胀节结构的有限元计算结果报告[R].合肥:合肥通用机械研究院,2004.7.
  • 2蔡善祥,马金华.重油催化裂化装置反应再生及能量回收系统管线失效分析与对策[A].第二届全国管道技术学术交流会议论文[C].2004.10.
  • 3GB16749-1997.压力容器波形膨胀节[S].[S].,..
  • 4.ASME高温结构设计规范(SECTION03 Ⅲ-D1-NH)-1999[S].,..

共引文献32

同被引文献31

引证文献2

二级引证文献13