摘要 介绍NIST测量LED总光通量的积分球系统,分析各项误差源的产生和大小,LED测量的不确定度根据管子的不同达到0.6%~2.3%.对有些观点如近场吸收,光谱失配和空间响应分布函数等对我国大多数读者来说可能是新鲜的.
作者 吕正
出处 《中国照明电器》 2006年第5期22-24,共3页 China Light & Lighting
  • 相关文献

参考文献6

  • 1C.Cameron Miller and Yoshi Ohno,Luminous Intensity Measurements of Light Emitting Diodes at NIST,LED Measurement Standard methods for specifying and measuring LED and LED cluster characteristics,CIE X022 -2001
  • 2Measurement of LEDs,CIE 127-1997
  • 3Ohno Y and Zong Y,Detector + Based Integrating Sphere Photometry,Proceedings,24th Sessionof the CIE Vol.1,Part 1,155~ 160(1999)
  • 4Ohno Y and Daubach ro,integrating Sphere Simulation on Spatial Nonuniformity Errors in Luminous Flux Measurement,J.IES,30-1,105 ~115(2001)
  • 5Ohno Y,Realizationof NIST 1995 Luminous Flux Scale using Integrating Sphere Method,J.lES,25-1,13 ~ 22(1996)
  • 6Ohno Y,A Numerical Method for Color Uncertainty,Proc.CIE Expert Symposium 2001 on Uncertainty Evaluation,Jan.2001,Vienna,Austria,8~ 11(2001)