期刊文献+

加热柱芯电极发射光谱测定化探样品中痕量金砷铋锑

Determination of Trace Elements in Geochemical Samples by Emission Spectrometry with a Heating Axis Electrode
在线阅读 下载PDF
导出
摘要 探讨了加热柱芯电极的蒸发和激发过程。利用ZnO为载体,Fe_2O_3作增强剂,MgO作稳定剂,碘溶液作卤化剂,样品不需化学预富集,使测金的检出限达到1:5万化探扫面要求,同时还可测定砷、铋、锑。各元素检出限分别为:1.l×l0-9Au,lx10-6As,0.l×l0-6Bi,2×l0-6Sb,试样分析的RSD(n=10)在4.2%~19.8%范围,质量符合要求。 A method for the determination of Au, As, Bi and Sb in geochemical samples by emission spectrometry with a heating axis electrode was developed. The mechanism of solid sample evaporation and excitation by this method was discussed. Samples were analyzed directly by using Fe_2O_3 as an enhancer,MgO as a stabilizer, I_2 as a halogenating agent and without any chemical preconcentration. The detection limits for Au,As Bi and Sb are 1.1x10 ̄(-9), 1x10 ̄(-6), 0.1x10 ̄(-6)and 2 x10 ̄(-6) respectively.The satisfactory results for these elements in geochemical samples were obtained with precision of 4.2% ~19.8% RSD(n=10).
作者 彭苏文
出处 《岩矿测试》 CAS CSCD 北大核心 1996年第2期129-134,共6页 Rock and Mineral Analysis
关键词 原子发射光谱 矿样 emission spectrometry geochemical sample gold arsenic antimony bismuth
  • 相关文献

参考文献11

二级参考文献11

  • 1沈慧君,地质实验室,1986年,2卷,3期,175页
  • 2沈瑞平,稀有元素及其矿物量的光谱分析,1983年
  • 3陈维范,1979年
  • 4团体著者,发射光谱分析,1977年
  • 5团体著者,岩石矿物光谱分析,1974年
  • 6殷宁万,分光化学分析,1956年
  • 7丁宝卿,岩矿测试,1987年,6卷,4期,274页
  • 8李学成,分析化学,1983年,11卷,8期,565页
  • 9孔永基,湖南冶金地质,1982年,10页
  • 10罗德Shen,分析化学,1980年,8卷,1期,77页