5Fan XQ,Li J,Zhu J,et al. Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures[J]. Ophthalmol Plast Reconstr Surg, 2003, 19:207-211.
6Saringer W, Nobauer-Huhmann I, Knosp E. Cranioplasty with individual carbon fibre reinforced polymere(CFRP) medical grade implants based on CAD/CAM technique[J]. Acta Neurochir,2002,144: 1193-1203.
7Mu X, Dong J, Chang T. Surgical reconstruction of the contracted eye socket and orbitozygomatichypoplasia in a one-stage operation [J]. Plast Reconstr Surg,1999,103:487-493.
8Jordan DR,Gilberg S,Bawazeer A. Coralline Hydroxyapatite Orbital Implant (Bio-Eye): Experience with 158 Patients [J]. Ophthalmol Plast Reconstr Surg,2004,20: 69- 74.
3Ono I,Gunji H,Suda K,et al.Orbital reconstruction with hydroxyapatite ceramic implants.Scand J Plast Reconstr Surg Hand Surg,1994,28:193-198.
4Saringer W,Nobauer-Huhmann I,Knosp E.Cranioplasty with individual carbon fibre reinforced polymere (CFRP) medical grade implants based on CAD/CAM technique.Acta Neurochir (Wien),2002,144:1193-1203.
6Eufinger H,Wittkampf AR,Wehmoller M,et al.Single-step fronto-orbital resection and reconstruction with individual resection template and corresponding titanium implant:a new method of computer-aided surgery.J Craniomaxillofac Surg,1998,26:373-378.
7Perry M,Banks P,Richards R,et al.The use of computer-generated three-dimensional models in orbital reconstruction.Br J Oral Maxillofac Surg,1998,36:275-284.
8Fan XQ,Li J,Zhu J,et al.Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures.Ophthalmol Plast Reconstr Surg,2003,19:207-211.
9Barker TM,Earwaker WJS,Lisle DA.Accuracy of stereolithographic models of human anatomy.Australas Radiol,1994,38:106-110.
10Holck DE,Boyd EM Jr,Ng J,et al.Benefits of stereolithography in orbital reconstruction.Ophthalmology,1999,106:1214-1218.
4Manolidis S, Weeks BH, Kirby M, et al. Classification and surgical management of orbital fractures: experience with 111 orbital reconstructions. J Craniofac Surg, 2002, 13 (6) :726-737.
5Klein M, Glatzer C. Individual CAD/CAM fabricated glassbioceramic implants in reconstructive surgery of the bony orbital floor. Plast Reconstr Surg, 2006, 117 ( 2 ) : 565-570.
6Schon R, Metzger MC, Zizelmann C, et al. Individually preformed titanium mesh implants for a true-to-original repair of orbital fractures. Int J Oral Maxillofac Surg, 2006, 35 ( 11 ) : 990 -995.
7Rinna C, Ungari C, Saltarel A, et al. Orbital floor restoration. J Craniofac Surg, 2005, 16(6): 968-972.
8Yavuzer R, Tuncer S, Basterzi Y, et al. Reconstruction of orbital floor fracture using solvent-preserved bone graft. Plast Reconstr Surg, 2004, 113(1) :34-44.
9Ozturk S, Sengezer M, Isik S, et al. Long-term outcomes of ultrathin porous polyethylene implants used for reconstruction of orbital floor defects. J Craniofac Surg, 2005, 16(6) :973-977.
10Villarreal PM, Monje F, Morillo AJ, et al. Porous polyethylene implants in orbital floor reconstruction. Plast Reconstr Surg, 2002, 109(3) : 877-885.