期刊文献+

应用牙科X线机探测口腔金属修复体的内在缺陷 被引量:1

Non-invasive detection of metal casting defects using dental X ray machine
在线阅读 下载PDF
导出
摘要 目的:探讨用牙科X线机探测钛、镍铬合金、钴铬合金铸件缺陷的可行性,同时分析金属铸件厚度对探测参数设置的影响。方法:按常规铸造方法制作3种厚度(1.0mm、0.6mm、0.3mm)的钛、镍铬合金、钴铬合金金属片,选用激光点焊机在金属表面打孔,模拟金属铸件铸造过程中产生的缺陷。调整牙科X线机各可调参数,在各参数下拍摄金属铸件照片,观察探伤结果。采用SPSS12统计软件包对数据进行组间t检验。结果:钛金属厚度对探伤参数设置的影响无统计学意义,P>0.05。镍铬合金和钴铬合金厚度对探伤参数设置的影响具有显著性差异,P<0.05。结论:钛金属铸件厚度对探伤参数设置的影响不大,可用牙科X线机代替专门的探伤机进行探测。 PURPOSE: The purpose of this in vitro study is to find the best parameters in detecting the casting defects made of titanium, nickel-chromium and chromium-cobalt using dental X ray machine. METHODS: Casting sheets in different thickness (1.0mm,0.6mm,0.3mm)were fabricated using of Ti, Ni-Cr and Cr-Co.Small pores on the surfaces were made with laser welder to simulate the internal porosity of the castings. Parameters of the dental X ray machine were adjusted to take films. The data were analyzed using SPSS12 software package for group t test. RESULTS: The thickness of Ti had no significant effect on the setting of the parameters of the dental X ray machine in detecting the defects of titanium castings (P〉0.05),while the thickness of Ni-Cr and Cr-Co had significant effect on the setting of the parameters (P〈0.05). CONCLUSION: Dental X ray machine can be used in deteoting the defects of titanium casting sheets. Supported by Shanghai Leading Academic Discipline Project (T0202).
出处 《上海口腔医学》 CAS CSCD 2006年第3期298-303,共6页 Shanghai Journal of Stomatology
基金 上海市重点学科(特色学科)建设项目(T0202)
关键词 金属铸件 无损伤检测 牙科X线机 Metal casting Non-invasive detection Dental X ray machine
  • 相关文献

参考文献12

  • 1Chai TI, Stein RS. Porosity and accuracy of multiple-unit titanium castings [J]. J Prosthet Dent ,1995,73(6):534-541.
  • 2Watanabe I, Watkins JH, Nakajima H, et al. Effect of pressure difference on the quality of titanium casting[J]. J Dent Res, 1997,76(3):773-739.
  • 3Cecconi BT, Koeppen RG, Phoenix RD, et al. Casting titanium partial denture frameworks: a radiographic evaluation [J]. J Prosthet Dent, 2002,87(3):277-280.
  • 4Al-Mesmar HS, Morgano SM, Mark LE. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks[J]. J Prosthet Dent, 1999,82(1):15-21.
  • 5Jang KS, Youn SJ, Kim YS. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks[J]. J Prosthet Dent, 2001,86(1):93-98.
  • 6Kikuchi M, Okuno O. Machinability evaluation of titanium alloys(Part 2)-Analyses of cutting force and spindle motor current [J].Dent Mater J, 2004,23(4):621-627.
  • 7Kobayashi E, Wang TJ, Doi H, et al. Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings [J]. J Mater Sci Mater Med,1998,9(10):567-574.
  • 8Yu SR, Zhang XP, He ZM, et al.Effects of Ce on the short-term biocompatibility of Ti-Fe-Mo-Mn-Nb-Zr alloy for dental materials[J]. J Mater Sci Mater Med, 2004,15(6):687-691.
  • 9Cortizo MC, De Mele MF, Cortizo AM. Metallic dental material biocompatibility in osteoblastlike cells: correlation with metal ion release[J]. Biol Trace Elem Res, 2004,100(2):151-168.