期刊文献+

碘吸收滴定法测定食品中二氧化硫残留量 被引量:28

Titration determination of sulfur dioxide residues in foods employing iodine solution absorbing
在线阅读 下载PDF
导出
摘要 对GB/T5009.34食品中亚硫酸盐蒸馏法的测定方法,进行一系列的改进,以淀粉溶液作指示剂用碘标准溶液滴定,边蒸馏边滴定,反应速度快,重现性好,回收率高,最低检出限为1mg/kg,适用于食品中亚硫酸盐及二氧化硫残留量的测定。 Determination of traces of sulphite in various foods was attempted by using the method of modified distillation of the national standard GB/T 5009.34. Effects of preparation of sulphite standard solution, optimum condition of the reaction were that indicator was starch solution and volumetric solution was iodine standard solution, destilled at the time of titration. The reaction velocity is rapid with good reproduction quality and high recovery rate. The minimum detectable quantity of this method was 1.0 mg/kg. The method could be applied to almost all kinds of foods.
出处 《食品与机械》 CSCD 北大核心 2006年第3期142-143,153,共3页 Food and Machinery
关键词 食品 亚硫酸盐 测定方法 改进 Food Sulphite Determination Improvenment
  • 相关文献

参考文献3

二级参考文献4

  • 1Hillery B, Elkins E, warner C, et al. Optimized MonierWilliams method for determination of sulfites in foods: Colladorative study[J]. J AOAC,1989, 72(3): 470-475.
  • 2日本药学会.卫生试验法·注解[M].北京:华文出版社,1995.66-67.
  • 3中国光学会光谱专业委员会.AOAC分析方法手册(上册)[M].,1984.708-709.
  • 4GB/T5009.34-2003.食品卫生检验方法理化部分[S].[S].,..