摘要
在碾压混凝土坝冷却水管模拟计算理论的分析基础上,提出适合于运用大型Ansys结构程序对高碾压混凝土坝进行仿真分析的水管冷却等效算法。通过应用于金安桥碾压混凝土坝的温度场仿真计算分析,在为设计提供了重要参考依据的同时,验证了该算法的合理性和实用性。
On the basis of analysis of the simulation theory for pipe cooling in RCC dam, an equivalent algorithm for pipe cooling is put forward, which is appropriate to be applied in the simulation analysis of high RCC dam using universal program of ANSYS. This algorithm is verified to be reasonable and practical through a case study of the Jin'anqiao RCC Dam temperature field simulation. The research provides very important references for design at the same time.
出处
《中国农村水利水电》
北大核心
2006年第10期71-75,共5页
China Rural Water and Hydropower