期刊文献+

基于护环技术的混凝土中钢筋腐蚀监测研究 被引量:7

FIELD CORROSION MONITORING OF REBARS IN CONCRETE BY GUARD RING ELECTRODE METHOD
在线阅读 下载PDF
导出
摘要 采用护环电极(Guard Ring Electrode,GRE,GE)测量方法,探讨辅助电极(CE)、护环电极(GE)在钢筋极化过程中的电流分配比,以及护环电极补偿电流的大小对正确测量研究区域内的钢筋极化电阻Rp的影响.结果表明,为获得较准确的极化电阻Rp值,即要将极化电流补偿在辅助电极CE的投影面积上,仅仅考虑到二维表面的电流(电位差)补偿是不够的.对于高阻混凝土(钝态钢筋)体系,简单的表面电流补偿导致测量的Rp值偏小,只有考虑到混凝土结构中三维空间的电流补偿,才可能得到准确的Rp值.同时将测量结果与均匀极化测量结果进行了对比.结果表明,对于活化态的钢筋混凝土体系,采用护环电极能够较好地将极化电流补偿在工作区域内,从而可对钢筋混凝土体系进行准确的腐蚀测量. When the general three - electrode system was used to detect corrosion rate of on - site large reinforced concrete, it was prone to result in non - uniform current distribution on the surface of rebars because of the large diffenence in size between counter electrode(CE) and work electrode(rebars). Therefore, polarization surface area of rebars was difficult to be decided. To solve the problem, guard ring electrode method(GEM) was ap- plied. The current ratio of CE and guard-ring electrode(GE) had been studied during polarization of rebars. Furthermore, the effect of GE current was also studied for the sake of obtaining accurate polarization resistance Rp value in the different corrosive states of rebars. In order to achieve real R p value, CE current must be compensat- ed in the projection rebar area below CE. During the experiment, the potential difference of concrete surface between RE2 and RE3 was monitored at all times. However, it is insufficient to consider only two - dimension current distribution. Generally very high concrete resistance tends to result in small measuring Rp value because of the insufficient compensation of CE current. In order to obtain real Rp value, three- dimension other than twodimension current distribution must be considered. Compared with uniform polarization results, it was found that CE polarization current could be compensated preferably in the projection area of rebars below CE by GEM when rebars were active, indicating that GEM can be used to monitor the corrosion behavior of rebars in concrete more accurately than other traditional linear polarization resistance method.
出处 《中国腐蚀与防护学报》 CAS CSCD 北大核心 2006年第5期257-262,共6页 Journal of Chinese Society For Corrosion and Protection
关键词 护环电极 均匀极化 钢筋混凝土 腐蚀 电流补偿 guard-ring electrode, uniform polarization, reinforced concrete, corrosion, current compensation
  • 相关文献

参考文献10

  • 1Montemor M F,Simoes A M P,Ferreira M G S.Chloride-induced corrosion on reinforcing steel:from the fundamentals to the monitoring techniques[J].Cement and Concrete Composites,2003,25 (4-5 SPEC):491-502
  • 2Feliu S,Gonzalez J A.Determining polarization resistance in reinforced concrete slabs[J].Corros.Sci,1989,29(1):105-113
  • 3Law D W,Millard S G,Bungey J H.Linear polarization resistance measurements using a potentiostatically controlled guard ring[J].NDT and E International,2000,33 (1):15-21
  • 4Sehgal A L D,Kho Y T,Osseo-Asare K,et al.Reproducibility of polarization resistance measurements in steel-in-concrete systems[J].Corrosion,1992,48(9):706-714
  • 5Wojtas H.Determination of polarization resistance of reinforcement with a sensorized guard ring:analysis of errors[J].Corrosion,2004,60(4):414-420
  • 6Stern M,Geary A L.Electrochemical polarization I.A theoretical analysis of the shape of polarization curves[J].J.Electrochem.Soc,1957,104(1):56-63
  • 7Alonso C,Andrade A,Gonzalez J A.Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types[J].Cement Concrete Res,1988,8:687-698
  • 8Feliu S,Gonzalez J A,Andrade C.Effect of current distribution on corrosion rate measurements in reinforced concrete[J].Corrosion (Houston),1995,51(1):79-86
  • 9Wojtas H.Determination of corrosion rate of reinforcement with a modulated guard ring electrode:analysis of errors due to lateral current distribution[J].Corros.Sci,2004,46(7):1621-1632
  • 10Song G L.Theoretical analysis of the measurement of polarization resistance in reinforced concrete[J].Cement &Concrete Composites,2000,22(6):407-415