摘要
河曲发电厂在改建过程中,需要拆除一座高40 m的晾水塔。该晾水塔周围环境复杂,距离高压线、地上光缆和居民区只有几米和几十米。针对复杂环境下的晾水塔拆除爆破,详细地论述了爆破方案的选择、爆破缺口的确定、爆破参数的选取、起爆网路的设计,实践证明,设计是成功的,为同类工程提供了一些有益的经验。
A cooling tower with 40 m in height in HEQU power plant needed be demolished in complicate surroundings. In this paper, a blasting plan about the blasting cut size, blasting parameters, blasting network, blasting vibration and safeguard of flying rock is put forward. Meanwhile, the results of the cooling tower are discussed.
出处
《爆破》
CSCD
2006年第4期49-52,共4页
Blasting
关键词
晾水塔
定向倾倒爆破
拆除爆破
cooling tower
directional blasting