支气管分泌物糖含量诊断误吸的效果评价

Evaluation on glucose content of bronchial secretions as a maker of mistake aspiration
在线阅读 下载PDF
导出
摘要 目的:探讨支气管分泌物糖含量诊断误吸的临床意义。方法:对27例创伤后昏迷患者鼻饲含放射性同位素锝的混合奶后,同时测定支气管分泌物的放射性计数与糖含量,并对两种方法进行比较。结果:支气管分泌物的糖含量与放射性计数不相关。结论:检测支气管分泌物中的糖含量诊断误吸尚存在一定问题。 Objective:To study the clinical significance of detecting glucose contents in the bronchial secretions. Methods :27 post-traumatic coma patients feeding food with Tc^99-DTPA, was measured radioactivity counts and glucose contents to diagnosis aspiration; the two methods was compared. Results: Through correlation analysis, radioactivity counts and glucose content in the bronchial secretion had no correlation. Conclusion:That detecting glucose contents in the bronchial secretions for diagnosis of mistake aspiration maybe still a problem to solve.
出处 《军医进修学院学报》 CAS 北大核心 2006年第6期461-462,共2页 Academic Journal of Pla Postgraduate Medical School
基金 "十五"全军医药卫生科研基金资助项目(01MA124)
关键词 创伤和损伤 葡萄糖 吸入 支气管 体内分泌物 wounds and injuries glucose inhalation bronchi bodily secretions
  • 相关文献

参考文献6

  • 1付春来,魏宏建.气管导管或气切套管套囊压力的测定及意义[J].中国急救医学,2004,24(5):387-388. 被引量:29
  • 2Barker PM,Boyd CA,Ramsden CA,et al.Pulmonary glucose transport in the fetal sheep[J].J Physiol,1989,409:15-27.
  • 3Metheny NA,St-John RE,Clouse RE.Measurement of glucose in tracheobronchial secretions to detect aspiration of enteral feedings[J].Heart Lung,1998,27(5):285-292.
  • 4Philips BJ,Meguer JX,Redman J,et al.Factors determining the appearance of glucose in upper and lower respiratory tract secretions[J].Intensive Care Medicine,2003,8; 134-142.
  • 5James P,Maloney T,Racey AR.Detection of aspiration in enterally fed patients:A requiem for bedside monitors of aspiration[J].JPEN(Journal of Parenteral and Enteral Nutrition),2002,26(6):S34-42.
  • 6Young PJ.A spoonful of sugar-improving the sensitivity of the glucose oxidase test strip method for detecting subclinical pulmonary aspiration of enteral feed[J].Anaesthesia and Intensive Care,2001,29(5); 539-543.

二级参考文献10

  • 1刘俊杰 赵俊.现代麻醉学[M](第二版)[M].北京:人民卫生出版社,1996.295.
  • 2Vyas D,Inweregbu K,Pittard A.Measurement of tracheal tube cuff pressure in critical care [J].Anaesthesia,2002,57(3):275-277.
  • 3Swaiss I,Badran I.Anesthesia apparatus:Cuff Mate-2,endotracheal cuff inflator and pressure monitor [J].Middle East J Anesthesiol,2003,17(2):311-318.
  • 4Luna CM,Legarreta G,Esteva H,et al.Effect of tracheal dilatation and rupture on mechanical ventilation using a low-pressure cuff tube [J].Chest,1993,104(2):639-640.
  • 5Karasawa F,Hamachi T,Takamatsu I,et al.Time required to achieve a stable cuff pressure by repeated aspiration of the cuff during anaesthesia with nitrous oxide [J].Eur J Anaesthesiol,2003,20(6):470-474.
  • 6O'Donnell JM.Oroyracheal tube intracuff pressure initially and during anesthesia including nitrous oxide [J]. CRNA,1995,6(2):79-85.
  • 7王联壁 贺喜强 李满珍.气管插管套囊过度充气导致气管裂开1例[J].临床麻醉学杂志,1996,12(6):346-346.
  • 8庄瑰霞.气管插管的技术管理体会[J].承德医学院学报,2001,18(1):56-57. 被引量:1
  • 9张汉湘,徐际盛,叶红艳.气管导管套囊注气量与气囊内压变化的关系[J].中国医师杂志,2002,4(1):43-44. 被引量:40
  • 10尤荣开,蒋贤高,邵朝朝.套囊压力监测在气管插管中的应用价值[J].中国急救医学,2003,23(4):266-267. 被引量:24