期刊文献+

旋转DSA及其在肝脏疾病诊断和介入治疗的应用 被引量:15

Application of rotational DSA in the diagnosis and interventional treatment of liver disease
在线阅读 下载PDF
导出
摘要 旋转DSA早在20世纪70年代早期第一次被应用在神经放射领域,随着技术及设备的不断进步,旋转DSA已经能使我们获得三维重建图像(3D DSA)。近年作为临床上较为实用的工具,已经应用于头颈部血管及腹部实质脏器疾病的诊断和治疗中。本文就旋转DSA在肝脏疾病的诊断和治疗中的应用做一综述。 The notational DSA was first proposed for the application as a managing tool of neuronradiology in the early 70's of 20th centery. Later on, throe dimensional image roconstruction(3D DSA) was aquirod along with the progressing development of technique and equipment devices. As a rather practical instrument, h has been utilized successfully in the diagnosis and management of head and neck vascular disorders, and abdominal parenchymal diseases during recent years. We comprehensively intoduce the application of rotational DSA for the diagnosis and management in hepatic diseases.
出处 《介入放射学杂志》 CSCD 2007年第3期209-212,共4页 Journal of Interventional Radiology
关键词 肝脏疾病 血管造影术 数字减影 放射学 介入性 Liver disease Angiography, digital subtraction Radiology,interventional
  • 相关文献

参考文献21

  • 1张玉琴,胡道予,黄艳荣.旋转DSA技术在腹部介入中的应用[J].放射学实践,2003,18(12):885-887. 被引量:11
  • 2Gailoud P,Oishi S,Carpenter P.Three-dementational digital angiography:new tool for simulaneous three-dimensional rendering of vascular and osseous information during rotational angiography[J].ANJR,2004,25:571 -573.
  • 3Kumazaki T.Development of rotational digital angiography and new cone-beam 3D imagine clinical value in vascular lesions[J ].Comput Methods Programs Biomed,1998,57:139-142.
  • 4周石,余雷,陈绪光,徐国斌,王帆,宋杰,王学建.旋转DSA三维重建成像与常规DSA在颈动脉狭窄诊治中的比较研究[J].中华放射学杂志,2005,39(1):92-96. 被引量:37
  • 5李文化,穆民,刘晓.三维数字减影血管造影技术诊断脑血管疾病的应用价值[J].介入放射学杂志,2005,14(2):119-121. 被引量:32
  • 6Sugahara T,Korogi Y,Nakashima K,et al.Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms[J].ANJR,2002,23:1545-1552.
  • 7Bidaut LM,Laurent C,Piotin M,et al.Second-generation threedimensional reconstruction for rotational three-dimentational angiography[J ].Acad Radiol,1998,5:836-849.
  • 8Hochmuth A,Spetzger U,Schumacher M.Com-parison of threedimensional rotational angiography in the assessment of ruptured cerebral aneurysms[J].ANJR,2002,23:1199-1205.
  • 9Ishihara S,Ross IB,Piotin M,et al.3D rotational angiography:recent experience in the evalution of cerebral aneurysm for treatment[J].Intervent Neurorad,2000,6:85-94.
  • 10Abe T,Hirohata M,Tanaka N,et al.Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm[J].AJNR,2002,23:686-688.

二级参考文献34

  • 1Hochmuth A,Spetzger U,Schumacher M. Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms[J]. Am J Neuroradiol,2002,23(7) : 1199-1205.
  • 2Seymour HR, Matson MB, Belli AM, et al. Rotational digital subtraction angiography of the renal arteries:Technique and evaluation in the study of native and transplant renal arteries[J]. Br J Radiol,2001,74 (878) : 134-141.
  • 3European Carotid Surgery Trialists Collaborative Group. Randomised trial of endarterectomy for recently symptomatic carotid stenosis : final results of the MRC European Carotid Surgery Trial(ECST). Lancet ,1998,351 : 1379-1387.
  • 4Porsche C, Walker L, Mendelow D, et al. Evaluation of cross-sectional luminal morphology in carotid atherosclerotic disease by using of soiral CT angiography . Stroke, 2001,32:2511.
  • 5Shah MV, Biller J. Indications for treatment of symptomatic atherosclerotic carotid artery disease ( Review ). Neurosurg Clin N Am ,2000,11:235-246.
  • 6Euopean Carotid Surgery Trialists' Collaborative Group. MRC european carotid surgery trial: interim results for symptomatic patients with severe (70% - 99% ) or with mild (0 - 29% ) carotidstenosis. Lancet, 1991,337 : 1235-1243.
  • 7Rothwell PM, Gibson R, Warlow CP. Inter-relation between plaque surface morphology and degree of ischemic stroke in patients with symptomatic carotid stenosis. Stroke,2000,32:615-630.
  • 8Moll R, Dinkel HP. Value of the CT angiography in the diagnosis of common carotid artery bifurcation disease: CT angiography versus digital subtraction angiography and color flow Doppler. Eur J Radiol,2001.39 : 155-162.
  • 9Elgersma OEH, Buijs PC, Wust AFJ, et al. Maximum internal carotid arterial stenosis: assessment with rotational angiography versus conventional intraarterial digital subtraction anyiography Radiology, 1999,213:777-783.
  • 10Hirai T, Korogi Y, Ono K, et al. Maximum stenosis of extracranial ICA effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA. Radiology,2001,221:802-809.

共引文献84

同被引文献85

引证文献15

二级引证文献81

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部