期刊文献+

氢化物原子荧光法测定化妆品中的痕量汞 被引量:1

Determination of Trace Mercury in Cosmetics by Hydride Atomic Fluorescence Method
在线阅读 下载PDF
导出
摘要 采用密闭微波消解技术对样品进行消解,用氢化物原子荧光法测定样品,改变仪器条件及所用溶液浓度,找出最佳仪器参数及各种因素对化妆品中汞测定的影响规律。本法的线性方程是If=181.248×c+0.333,加标回收率在97.8%~102.4%之间,相对平均偏差RSD为2.78%。本法具有操作简便、精密度好、灵敏度及回收率高的特点,有一定的实用意义。 Using the closed microwave digestion technology, the cosmetic samples were digested. The determination was carried out by the hydride atomic fluorescence method. When the parameters of the equipment and the concentrations of the solutions were varied, the best parameters of the equipment and the influencing rule of the various factors on the determination of trace mercury in cosmetics were found. By this method, the linear equation was calculated as If = 181. 248 × c + 0.333. The corresponding averages recovery rate were between 97.8 % and 102.4 %. The relative standard deviation (RSD) was 2.78 %. This method was simple manipulation, good accuracy, high sensitivity, highly recovery rate and practicality significant.
作者 李冬梅
出处 《广州化工》 CAS 2007年第3期64-65,共2页 GuangZhou Chemical Industry
关键词 氢化物原子荧光法 化妆品 硼氢化钾 hydride atomic fluorescence cosmetics potassium borohydride mercury
  • 相关文献

参考文献2

二级参考文献3

  • 1.中华人民共和国国家标准汇编化妆品卫生化学标准检验方法汞[S].GB7917.1—87[M].北京,中国标准出版社,1995.141-143.
  • 2.中华人民共和国国家标准汇编化妆品卫生化学标准检验方法砷[s].GB7917.2-87[M].北京,中国标准出版社,1995.144—148.
  • 3胡家英,丁刚,施宏景.双道氢化物发生原子荧光法同时测定水中砷汞[J].中国卫生检验杂志,2000,10(6):686-687. 被引量:25

共引文献18

同被引文献5

引证文献1

相关作者

内容加载中请稍等...