期刊文献+

腺苷负荷试验核素心肌灌注显像检查的护理配合 被引量:3

在线阅读 下载PDF
导出
摘要 腺苷负荷试验核素心肌灌注显像检查,是在患者静脉注射腺苷及放射性核素显像剂^99mTc-甲氧基异丁基异晴(MI—BI)后,心肌处于负荷状态时进行单光子发射型计算机断层照相机(Single Photon Emission Computed Tomography,SPECT)扫描,能准确评估心肌血流灌注及储备情况,为冠心病的诊断、危险度的分层及其对预后的评价提供了可靠的依据。2004年11月-2005年11月我科应用德国Siemens E.CAM^+SPECT为5例患者进行哔项检查,护理体会总结如下。
出处 《现代护理》 2007年第06X期1753-1754,共2页 Modern Nursing
  • 相关文献

参考文献3

  • 1Mohiuddin Sm,Ravage CK,Esterbooks DJ,et al.The comparative safety and diagnostic accuracy of adenosine myocardial perfusion imaging in women versus men[J].Pharmacotherapy,1996,16:646-651.
  • 2李云春,管昌田.药理学应激心肌灌注显像[J].生物医学工程学杂志,2000,17(4):457-460. 被引量:2
  • 3陈盛祖.临床技术操作规范.核医学分册[M].北京:人民军医出版社,2004:110-112.

二级参考文献1

  • 1Yong D Z,Am J Noninvas Cardiol,1987年,1卷,1期,11页

共引文献1

同被引文献25

  • 1陈桂娥.碘海醇与泛影葡胺在CT增强扫描中不良反应的比较[J].实用诊断与治疗杂志,2006,20(2):132-133. 被引量:8
  • 2李少林.心肌灌注显像[A].见:李少林.核医学:第5版[C].北京:人民卫生出版社,2002.140-146.
  • 3ISKANDRIAN A S,HEO J,NGUYEN T,et al.Assessment of coronary artery disease using singlephoton emission computed tomography with thallium-201during adenosine-induced coronary hyperemia[J].Am J Cardiol,1991,67:1190.
  • 4高东宸.药物不良反应监察指南[M].北京:原子能出版社,1994:179.
  • 5Hendel RC, Berman DS, Di Carli MF, et al. ACCF/ASNC/ACR/ AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: a report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine: endorsed by the American College of Emergency Physicians[J]. Circulation, 2009, 119:e561-e587.
  • 6Hendel RC, Patel MR, Kramer CM, et al. ACCF/ACR/SCCT/ SCMR/ASSC/NASCI/SCA:/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Corr:nittee Appropriateness CriteriaWorking group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology[J]. J Am Coil Cardiol, 2006,48: 1475-1497.
  • 7Schwitter J, Wacker CM, van Rossum AC, et al. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial[J]. Eur Heart J, 2008,29: 480-489.
  • 8Brodoefel H, Burgstahler C, Tsiflikas I, et al. Dual- source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J]. Radiology, 2008,247: 346-355.
  • 9Meijboom WB, Meijs MF, Schuijf JD, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study[J]. J Am Coil Cardiol, 2008,52:2135-2144.
  • 10Carrigan TP, Nair D, Schoenhagen P, et al. Prognostic utility of 64-slice computed tomography in patients with suspected but no documented coronary artery disease [J]. Eur Heart J, 2009,30:362-371.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...