摘要
该文运用等放热降法,分析计算了锅炉过热器和再热器喷水减温对电厂经济性的影响,获得了喷水域温系统合理设计、改造及运行的技术依据.
Influence of attemperation, used in superheaters and reheaters on The economy ot powerplants,is being calculated with the equivalent heat drop method,providing data useful for design,retrofit and operation of attemperation systems.
出处
《发电设备》
1997年第1期14-18,共5页
Power Equipment