期刊文献+

MTT法检测rhEGF生物活性 被引量:7

Detection of rhEGF bioactivity by MTT assay
在线阅读 下载PDF
导出
摘要 目的鉴于待测的生物活性因子均有适于其自身的最佳测定条件,规范了重组表皮生长因子(rhEGF)的MTT测定法。方法根据MTT测定法原理,在3个因素(每孔细胞数、MTT和胎牛血清浓度)及3个水平上进行了正交实验设计。结果MTT检测法的最佳条件是:Balb/c3T3细胞悬液(5×107cells·L-1)100μl·well-1,MTT(8g·L-1)20μl·well-1,FBS(1·5%)100μl·well-1。结论上述正交实验规范的MTT最佳实验条件,适用于Balb/c3T3细胞活性的检测及其药物抑制性实验。但在测定rhEGF生物活性时,为使对照孔细胞数保持在较低水平以便给生物活性因子留有适当的余地以显示其促细胞增殖活性,建议FBS浓度采用0·5%。 Aim Because the activity of a given bioactive factor to be detected has its own optimal conditions for detection, the MTT method for rhEGF assay was defined in this paper. Methods According to the principle of MTT assay, an orthogenal test was designed with three factors ( cell per well, MTT and fetal bivine serum concentrations) at three destinct levels. Results The optinum conditions for MTT assay were as follows: Balb/c 3T3 cell suspension (5 × 10^7 cell·L^-1 ) 100 μl·well^-1 , fetal bovine serum(1.5% )100 μl·well^-1. MTT (8 g· L^-1) 20 μl·well^-1. Conclusions The above-mentioned optimal conditions for MTT assay defined by the orthogona ltest is suitable for the detection of Balb/c 3T3 cell bioactivity and its druginhibition test. However in the ease of rhEGF assay, the cell counts of the control have to keep at a lower level in order to leave appropriate leeway to show the proliferation activity of the bioactive factor, thus a concentration of 0. 5% of FBS is recommended while rhEGF activity is detected.
出处 《中国药理学通报》 CAS CSCD 北大核心 2007年第6期827-829,共3页 Chinese Pharmacological Bulletin
基金 军队"十五"重点课题基金资助项目(No01z023)
关键词 rhEGF活性 MTT法 正交实验 rhEGF activity MTT assay, orthogonal assay
  • 相关文献

参考文献10

二级参考文献43

共引文献81

同被引文献54

引证文献7

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部