摘要
提出一种组合式空气处理系统,在结构上采用复叠形式。该系统能够按照不同运行模式实现对空气的降温、除湿、加热和加湿处理。对两级冷冻除湿过程进行分析,并对系统流程和结构进行改进。与传统空气处理方式相比,组合式空气处理系统一方面避免分别购置空气处理设备,另一方面扩大系统工作的环境温度范围和空气的热湿处理范围。
Presents a kind of combined air treating system, adopts cascade style configuration. This system can implement cooling, dehumidification, heating and humidification according to different operation modes. Analyzes the two-stage refrigeration dehumidification, also improves the system's flow and configuration. Compared with the traditional air handling system,this system can decrease investment of equipment, also can extend the scope of environment temperature under which the system works and of temperature and humidity which the system can dispose.
出处
《制冷与空调》
2007年第5期33-37,46,共6页
Refrigeration and Air-Conditioning
关键词
湿度
高温热泵
冷冻除湿
复叠循环
humidity
high temperature heat pump
refrigeration dehumidification
cascade cycle