摘要 毛细管光学元件在X射线分析中的应用已有20多年的历史,在这段时间里,毛细管光学元件的制作技术发生了很大的变化。上世纪90年代初,使用的是组装的毛细管光学元件,目前,集成的多通道毛细管光学元件已广泛地应用于市场销售的X射线分析设备中。这些元件的毛细管直径在微米量级,其光学性质可以根据几何光学的光线追迹计算进行描述。最近,由于多通道毛细管制作技术的改进,已成功制成了200 nm及以下通道尺寸的毛细管光学元件。在这样小的通道尺寸下,观察到了X射线辐射的波动效应。最后文章介绍了毛细管光学元件在X射线微荧光分析和微衍射方面的应用。 For more than 20 years, capillary optics have been used in X-ray analytics. During this time the technology of manufacturing capillary optics passed a considerable development. Whereas in the beginning of 1990s assembled capillary optics were tested in research laboratories, at present monolithic polycapillary optics are widely used in commercial X-ray analytical instruments. These optics show capillary sizes in the micrometer region and their physical behaviour can be described in terms of geometrical optics using ray tracing programs. Recently capillary channel sizes of 200 nm and below were realised due to further improvement of the manufacturing technology for polycapillary structures. At such small structures, the appearance of wave effects for X-ray radiation was observed. Finally, application 'examples for capillary optics in micro X-ray fluorescence analysis and micro X-ray diffractometry are presented.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2007年第12期1932-1945,共14页 Optics and Precision Engineering
关键词 X射线毛细管光学元件 波动特性 纳米毛细管 X射线分析 X-ray capillary optics wave properties nanocapillary X-ray analytics
  • 相关文献

参考文献34

  • 1COMPTON A H. The total reflection of X-rays[J]. Phil. Mag,1923,45:1121.
  • 2JENTZSCH F. Optische Versuehe mit Rontgenstrahlen (Optical Experiments with X-Rays)[J]. Phys. Zeitschrift, 1929,30 : 268-273.
  • 3KUMAKHOV M A. Radiation of Channeled Particles in Crystals[M]. Moscow: Energoatomizdat, 1986.
  • 4ARKADEV V A, KOLOMIITSEV A I, KUMAKHOV M A,et al.Wide-band X-ray optics with a large angular aperture[J]. Soy. Phys. Usp,1989,32:271-276.
  • 5YANG Y M,DING X L. An investgation of X-ray fluorescence analysis with an X-ray focusing system (X-ray lens) [J]. Nucl. Instr. and Meth. in Phys. Res. B,1993,82:121-124.
  • 6GAO N,JANSSENS. Polycapillary X-Ray Optics, in X-Ray Spectrometry: Recent Rechnological Advances[M]. John Wiley & Sons Ltd,2004.
  • 7BJEOUMIKHOV A, LANGHOFF N,BJEOUMIKHOVA S,et al. Capillary optics for micro X-ray fluorescence analysis[J]. Rev. Sci. Instrum ,2005,76:063115-063115-7.
  • 8ARKADIEV V A,BZHAUMIKHOV A A.X-ray focusing in capillary slructures[J]. SPIE,1996, 2859:131-139.
  • 9DABAGOV S B, KUMAKHOV M A, NIKITINA S V. On the interference of X-rays in multiple reflection optics [J].Phys. Lett. A,1995, 203:279-282.
  • 10DABAGOV S B. Channeling of neutral particles in micro-and nanocapillaries[J]. Physics Uspekhi ,2003, 46:1053-1076.

同被引文献20

  • 1王庆有,金贵,刘海军.玻璃管参数的同步测量系统设计[J].电子测量技术,2007,30(1):157-159. 被引量:3
  • 2http://www.glassinfo.com.cn/,玻璃信息网[OL].
  • 3郁道银,谈恒英.光学工程[M].北京:机械工业出版社,2007(2):67-73.
  • 42WA-J型阿贝折射仪使用说明书,上海光学仪器五厂生产.
  • 5孟尔熹,曹尔第,编.试验误差与数据处理[M].上海:上海科学技术出版社,1988,1:66-70.
  • 6SEONGSIK CHANG.Lasing Characteristics of Deformed Micro cavities[D].Yale University,1998:74-77.
  • 7普小云,白然,邢曼男等.用玻璃毛细管精确测量微量液体的折射率[P].国家发明专利.专利申请号:2007100660162
  • 8http://www.glassinfo.corn.cn/,玻璃信息网[0L].
  • 9JENNINGS W. Gas chromatography with glass capillary columns [M]. New York: Second Edi- tion, Academic Press, 1980.
  • 10DANDENEAU R D, et al: Glass capillary chro- matography EC]. Third International Symposium (R. E. Kaiser Edition). Institute of Chromatogra- phy Bad Diirkheim ,1979: 81.