期刊文献+

Changes of Resistance During Polyelectrolyte-enhanced Stirred Batch Ultrafiltration

Changes of Resistance During Polyelectrolyte-enhanced Stirred Batch Ultrafiltration
在线阅读 下载PDF
导出
摘要 The permeation flux or the resistance in the ultrafiltration process is mainly limited by osmotic pressure, and it may originate from various kinds of polymer interactions. However, the real origin of permeation resistance hasn't been clarified yet in the light of polymer solution nature. The removal of nitrate contamination by polyelectrolytes was carried out with stirred batch ultrafiltration. The polyelectrolyte concentrations both in permeate and retentate were analyzed with total organic carbon analyzer and permeate mass was acquired by electronic balance connected with computer. The total resistance was calculated and interpreted based on the osmotic pressures in three concentration regimes. In the dilute region, the resistance was proportional to polymer concentration; in the semidilute region, the resistance depended on polymer concentration in the parabolic relationship; in the highly concentrated solution regime, the osmotic pressure factor (OPF) would dominate the total resistance; and the deviation from OPF control could come from the electrostatic repulsion between the tightly compacted and charged polyelectrolyte particles at extremely concentrated solution regime. It was first found that dilute and semidilute concentration regions can be easily detected by plotting the leg-log curves of the polymer concentration versus the ratio of the total resistance to polymer concentration. The new concept OPF was defined and did work well at highly concentrated regime. The permeation flux or the resistance in the ultrafiltration process is mainly limited by osmotic pressure, and it may originate from various kinds of polymer interactions. However, the real origin of permeation resistance hasn’t been clarified yet in the light of polymer solution nature. The removal of nitrate contamination by polyelectrolytes was carried out with stirred batch ultrafiltration. The polyelectrolyte concentrations both in permeate and retentate were analyzed with total organic carbon analyzer and permeate mass was acquired by electronic balance connected with computer. The total resistance was calculated and interpreted based on the osmotic pressures in three concentration regimes. In the dilute region, the resistance was proportional to polymer concentration; in the semidilute region, the resistance depended on polymer concentration in the parabolic relationship; in the highly concentrated solution regime, the osmotic pressure factor (OPF) would dominate the total resistance; and the deviation from OPF control could come from the electrostatic repulsion between the tightly compacted and charged polyelectrolyte particles at extremely concentrated solution regime. It was first found that dilute and semidilute concentration regions can be easily detected by plotting the log-log curves of the polymer concentration versus the ratio of the total resistance to polymer concentration. The new concept OPF was defined and did work well at highly concentrated regime.
出处 《Journal of Donghua University(English Edition)》 EI CAS 2007年第4期478-483,共6页 东华大学学报(英文版)
关键词 ultra filtration permeation resistance semi-dilute solution overlap concentration polymerchain collapse 超滤法 抗渗透性 高分子电解质 分离方法
  • 相关文献

参考文献10

  • 1S . K. Zaidi,A. Kumar.Experi mnetal studies in the dead- end ultrafiltration of detran: analysis of concentration polarization[].Separation and Purification Technology.2004
  • 2J Paris,P Guichardon,F Charbit.Transport phenomenain ultrafiltration: a new two-di mensional model compared with classical models[].Journal of Membrane Science.2002
  • 3T.-W. Cheng,H.-M. Yeh,and C.-T. Gau.Flux analysis by modified os motic-pressure model for laminar ultrafiltration of macromolecular solutions ,Sep[].Purification Technol.1998
  • 4P. Bacchin,D. Si-Hassen,V. Starov , et al.A unifying model for concentration polarization, gel-layer for mation and particle depositionin cross-flow membrane filtration of colloidal suspensions[].Chemical Engineering Science.2002
  • 5P. Bacchin,M. Meireles,and P. Ai mar.Modelling of filtration:fromthe polarizedlayer to deposit for mation and compaction[].Desalination.2002
  • 6A.-S .J nsson,and B.J nsson.Ultrafiltration of colloidal dispersions — a theoretical model of the concentration polarization phenomena ,J[].Coll Interf Sci.1996
  • 7E. K. Zholkovskij,J . Czarnecki,and J . H. Masliyah.Electrostatic repulsion in concentrated disperse systems I contribution of electrostatic interaction to os motic pressure[].J Coll Interf Sci.2001
  • 8W. R. Bowen,A. Mongruel,and P. M. Williams.Prediction of the rate of cross-flow membrane ultrafiltration:a colloidal interaction approach[].Chem Eng Sci.1996
  • 9W. R. Bowen,F. Jenner.Dynamic ultrafiltration model for charged colloidal dispersions : a Wigner-Seitz cell approach[].Chem Eng Sci.1995
  • 10S . E. Pedrosa,C. Grosse.Numerical analysis of the concentration polarization in colloidal suspensions : comparison withtheoretical predictions[].Journal of Colloid and Interface Science.1999

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部