期刊文献+

ProPex测量仪对磨牙根管工作长度准确性的临床评价 被引量:9

The clinical observation of the accuracy in molar root canal working length measurement with Propex apex locator.
原文传递
导出
摘要 目的:评价ProPex根管测量仪测量磨牙根管工作长度的准确性。方法:选择50例根尖周病患者,共102个磨牙。患牙随机分为两组,实验组采用ProPex根管测量仪测量根管工作长度,对照组采用X线法计算根管工作长度,常规根管预备充填,摄X线牙片了解其准确性。结果:实验组根管充填适充率显著高于对照组(p<0.05)。结论:ProPex根管测量仪方便、快捷,能够准确测量根管长度。 Objective: To evaluate the accuracy of the Propex apex locator in molar canal working length measurement. Method: 102 molars from 50 periodontitis patients were divided into two groups. The root canals of the experiment group and the control group were measured by Propex apex locator and the X-ray respectively. All canals were prepared and filled. The accuracy was evaluated by radiological observation. Result: The successful ratio of root canal therapy of the experimental group was significantly higher than that of the control group (p 〈 0.05). Conclusion: The Propex apex locator is more accurate in the posterior tooth root canal length measuring.
出处 《临床口腔医学杂志》 2008年第1期33-34,共2页 Journal of Clinical Stomatology
关键词 根管测量仪 根管工作长度 磨牙 apex locator root canal working length molars
  • 相关文献

参考文献3

  • 1Dunlap CA, Remeikis NA,BeGole EA, et al. An In Vivo Evaluation of an Electronic Apex Locator that Uses the Ratio Method in Vital And Necrotic Canals [J]. J Endodon, 1998, 24 (1) : 48-50.
  • 2Kovacevic M,Tamarut T. Influence of the concentration of Ions And Foramen Diameter on the Accuracy of Electronic Root Canal Length Measurement-an Experimental Study [J]. J Endodon, 1998,24 (5): 346-351.
  • 3Kobayashi C. Electronic Canal Length Measurement [J].Oral Sur Oral Med Oral Path, 1995,79(2) :226-231.