期刊文献+

碳纳米管修饰传感器对农药敌草隆的快速测定方法研究 被引量:6

Electrochemical Sensor Based on Multi-wall Carbon Nanotubes for the Detection of Diuron
在线阅读 下载PDF
导出
摘要 利用多壁碳纳米管修饰玻碳电极(MWCNTs/GC),对除草剂敌草隆进行了电化学性质研究及快速检测,实验表明,MWCNTs修饰电极能有效地促进敌草隆在电极表面的电子传递速度,通过对敌草隆的电催化氧化作用,提高对敌草隆响应的灵敏度并有效降低敌草隆的检测限。以循环伏安法(CV)及示差脉冲伏安法(DPV)研究了该修饰电极的电化学性质并优化了对敌草隆测定的最佳条件,结果表明MWCNTs/GC对敌草隆具有良好的催化氧化作用,在+0.97V处的敌草隆电流响应与其浓度在0.14-14.32μg/mL的范围内呈良好的线性关系,最低检测限达0.03μg/mL(S/N=3);回收率检测实验表明,敌草隆标准样品在蔬菜样品中的回收率在94%~105%之间。该传感器灵敏度高、稳定性好,在环境监测、食品检验等领域中将具有很好的应用前途。 In this study ,multi-wall carbon nanotubes(MWCNTs)was used for fabrication of electrochemical sensor for the detection of herbicide diuron.It exhibited good electrochemical response at the MWCNTs electrods surface.The electrochemical characterization and voltammetric performance of diuron were evaluated by using Cyclic Voltammetric(CV)and Differential Pulse Voltammetric(DPV).tHE AMOUNT OF mwcnts AND pH of the electrolyte have been optimized.Under the optimized condition,electrochemica sensor modified with MWCNTs exhibited promising voltammetric performances,and the current response was well linear over the 0.14-14.32 μg/mL diuron range with the detection limit of 0.03μg/mL(S/N=3).The recoveries of diuron in samples are between 94% and 105%,which shows that it is a sensitive and stable method,and has promising application in food inspection.
机构地区 华东师范大学
出处 《上海化工》 CAS 2008年第6期12-17,共6页 Shanghai Chemical Industry
关键词 多壁碳纳米管 敌草隆 检测 MWCNTs Diuron Electrochemical sensor
  • 相关文献

参考文献25

  • 1Martinez Gaera M, Marinez Vidal J L, Garrido Frenich A. Spectrophotometric method to determine ternary mixtures of atrazine, diuron, and ehlorpyrifos in water and soil by a ratio spectrum-zero crossing method. J. Assoe Off Anal Chem, 1995,78(2):423-430.
  • 2任晋,黄翠玲,赵国栋,蒋可.固相萃取-高效液相色谱-质谱联机在线分析水中痕量除草剂[J].分析化学,2001,29(8):876-880. 被引量:52
  • 3Castro R, Moyano E, Galceran M T. On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides. J. Chromatogr. A, 2000, 869: 441-449.
  • 4Trojanowicz M, Hitchman M L. A potentiometric polypyrrole-based glucose biosensor. J. Trends in Anal. Chem, 1996, 15: 38-44.
  • 5Yulaev M F, Sitdikov R A, Dmitrieva N M, et al. Development of a potentiometric immunosensor for herbicide simazine and its application for food testing. J. Sensors Actuators B: Chem, 2001, 75:129-135.
  • 6Keay R W; McNeil C. Separation-free electrochemical immunosensor for rapid determination of atrazine. J. Biosensors Bioelectron, 1998, 13: 963-970.
  • 7Mastin J P, Striley C A F, Biagini R E, et al. Development and validation of an ELISA for metolachlor mereapturate in urine. J. Anal. Chim. Acta, 1999, 376: 119-124.
  • 8Koblizak M, Masojidek J, Komenda J, et al. A sensitive photosystem Ⅱ-based biosensor for detection of a class of herbicides. J. Biotech. Bioeng, 1998, 60: 664-669.
  • 9Giardi M T, Kobl i zek M, Masoj i dek. Photosystem Ⅱ -based biosensors for the detection of pollutants. J. Biosensors Bioelectron, 2001, 16:1027-1033.
  • 10Carpentier R, Loranger C, Chartand J, et al. Protein and chlorophyll in photosystem-ii probed by infrared-spectroscopy. J Anal. Chim. Acta, 1991, 249: 55-60.

二级参考文献12

共引文献92

同被引文献109

引证文献6

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部